Results 211 to 220 of about 2,963 (263)
Some of the next articles are maybe not open access.
Surface evaporation of turbulent falling films
International Journal of Heat and Mass Transfer, 1991Abstract In refrigeration and heat pump applications, falling film evaporators should be very attractive due to high heat transfer coefficients with negligible pressure drop. In this paper results from an experimental study with refrigerant R12 are reported.
Anders Åsblad, Thore Berntsson
openaire +1 more source
The falling film MSF evaporator
Desalination, 1976Abstract The application of falling film heat transfer to the MSF cycle permits use of CO2 for scale prevention at no cost and the building of efficient very small capacity units with heating surfaces that are fully accessible during operation. It also becomes possible to use doubly fluted tubes for a 2 3 saving in heating surface requirements.
openaire +1 more source
Falling film evaporation of binary mixtures
AIChE Journal, 1994AbstractThe interactive effects of heat and mass transfer in evaporation of binary mixtures flowing as falling films on vertical surfaces was investigated. Evaporative heat‐transfer coefficients were measured for aqueous mixtures of ethylene and propylene glycol, with boiling ranges up to 55°C.
J. W. Palen, Qi Wang, J. C. Chen
openaire +1 more source
Falling Film Evaporation in a Rectangular Channel With Different Depth
10th International Conference on Nuclear Engineering, Volume 4, 2002This paper describes the results of experimental tests carried out to study falling film evaporation on a heated flat plate with countercurrent air flowing in a rectangular channel. Experimental tests have been run with different channel depths with respect to a previous facility configuration in order to evaluate the effect of this parameter on the ...
FORGIONE, NICOLA +3 more
openaire +2 more sources
Evaporation of pure liquids with increased viscosity in a falling film evaporator
Heat and Mass Transfer, 2007The present study investigated fluid dynamics and heat transfer of viscous pure liquids in a falling film evaporator. This is of special benefit as it avoids mass transfer effects on the evaporation behaviour. Experiments at a single-tube glass falling film evaporator were conducted.
Felix Weise, Stephan Scholl
openaire +1 more source
Alcohol recovery in falling film evaporators
Applied Thermal Engineering, 2002Falling film evaporators can be used to recover alcohol and other volatile compounds from waste products, and as part of the primary production process. A simple model has been developed to predict the performance of the equipment. Measurements made on commercial installations have confirmed the validity of the model over a range of operating ...
openaire +1 more source
Desalination and Water Treatment, 2014
AbstractHorizontal-tube falling film technology is widely used in multi-effect desalination plant. The film characteristics of falling water film outside the tubes in horizontal-tube falling film evaporator were simulated. The numerical result was compared with the experimental result and they were proven with good agreement.
Qing-gang Qiu +4 more
openaire +1 more source
AbstractHorizontal-tube falling film technology is widely used in multi-effect desalination plant. The film characteristics of falling water film outside the tubes in horizontal-tube falling film evaporator were simulated. The numerical result was compared with the experimental result and they were proven with good agreement.
Qing-gang Qiu +4 more
openaire +1 more source
Calcium sulphate scaling in falling film evaporators
Desalination, 1974Abstract The formation of calcium sulphate scale in Vertical Tube Evaporators (VTE) of the falling film type has been investigated in a single tube experiment using fluted tubes. It was found that the scaling threshold is dependent not only on the brine concentration and temperature, but also on the heat flux to the evaporating film.
T.D. Hodgson, M.N. Elliot, T.W.J. Jordan
openaire +1 more source
Scale deposition from an evaporating falling film
Desalination, 1975Abstract A study was made of the factors governing CaCO3 scale deposition from an evaporating falling film, on a heated aluminum tube. A kinetic model was developed describing scale layer growth. The results of this work provide a basic background enabling a more rational approach for conducting practical work related to the scaling problem.
E. Gazit, D. Hasson
openaire +1 more source
MICRO-evaporation in a falling film contactor
2010Poster presentation - no abstract.
Moschou, P. +3 more
openaire +1 more source