Results 61 to 70 of about 792,011 (298)
Research on Access Mode of the Flexible DC Power Distribution System into AC System
The connection mode of the direct current (DC) power distribution system and the alternating current (AC) system is the foundation of system design, and it is also one of key technologies of the DC power distribution network.
Yao Liu +5 more
doaj +1 more source
Multi-Timescale-Based Fault Section Location in Distribution Networks
To meet the requirements of quickness and accuracy for fault location in smart distribution networks with high penetration of distributed generations, we propose an integrated fault section location method based on multiple timescales. On the millisecond
Qingle Pang +5 more
doaj +1 more source
Spatio-temporal evolution of intraplate strike-slip faulting: the Neogene-Quaternary Kuh-e-Faghan Fault, Central Iran [PDF]
Central Iran provides an ideal region to study the long-term morphotectonic response to the nucleation and propagation of intraplate faulting. In this study, a multidisciplinary approach that integrates structural and stratigraphic field investigations ...
Berberian +24 more
core +3 more sources
This study reveals a unique active site enriched in methionine residues and demonstrates that these residues play a critical role by stabilizing carbocation intermediates through novel sulfur–cation interactions. Structure‐guided mutagenesis further revealed variants with significantly altered product profiles, enhancing pseudopterosin formation. These
Marion Ringel +13 more
wiley +1 more source
A Practical Protection Coordination Strategy Applied to Secondary and Facility Microgrids
In a conventional distribution system, protection algorithms are designed to operate on a unidirectional high fault-current level. In a microgrid, a fault current from distributed generation (DG) may bring about a relay malfunction because of the ...
Woo-Kyu Chae +5 more
doaj +1 more source
For multiple distributed generation units (DG unit) parallel system, excessive fault current has adverse effects on the safe and stable operation of the utility grid.
Hongwei Fang +3 more
doaj +1 more source
Modular multilevel converter with modified half-bridge submodule and arm filter for dc transmission systems with DC fault blocking capability [PDF]
Although a modular multilevel converter (MMC) is universally accepted as a suitable converter topology for the high voltage dc transmission systems, its dc fault ride performance requires substantial improvement in order to be used in critical ...
Abdelsalam, Ibrahim A. +3 more
core +2 more sources
Biomolecular condensates formed by fused in sarcoma (FUS) are dissolved by high ATP concentrations yet persist in cells. Using a reconstituted system, we demonstrate that valosin‐containing protein (VCP), an AAA+ ATPase, counteracts ATP‐driven dissolution of FUS condensates through its D2 ATPase activity.
Hitomi Kimura +2 more
wiley +1 more source
This paper presents a novel analytical method (NAM) of inductance identification for a direct drive permanent magnet synchronous motor (DDPMSM) with a stator winding fault (SWF), which considers the spatial position of the shorted turns.
Caixia Gao +4 more
doaj +1 more source
A Fault Tolerance Method for Multiple Current Sensor Offset Faults in Grid-Connected Inverters
Three-phase grid-connected inverters have been widely used in the distributed generation system, and the current sensor has been applied in closed-loop control in inverters. When the current sensor offset faults occurs, partial fault features of multiple
Fan Zhang +6 more
doaj +1 more source