Wind turbines should have fault ride through capability, and also it can provide damping for the power grid by improving the control strategy. However, the currently corresponding control strategy is designed independent for the fault voltage through ...
Haiyan Tang +3 more
doaj +2 more sources
Transmission distribution coordination for DER fault ride through support
Rapid renewable energy sources (RESs) deployments in transmission and distribution networks have changed power systems’ operation and control mechanisms.
Ha Thi Nguyen +7 more
doaj +2 more sources
Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid.
Huabo Shi +7 more
doaj +2 more sources
Mechanical Switch Based Adaptive Fault Ride-through Strategy for Power Quality Improvement Device
Cascaded H-bridge power quality improving device (PQID) has garnered extensive attention for its flexible electric energy conversion and fast voltage response.
Yu Shen +6 more
doaj +2 more sources
Fault Ride Through approach for Grid-Connected Photovoltaic System
This paper presents a fault ride-through approach for grid-connected photovoltaic (PV) systems, aimed at improving the system's response during voltage sags and limiting the maximum inverter current during symmetrical faults.
Komal Bai +2 more
doaj +2 more sources
The low voltage direct current (LVDC) distribution networks are connected with too many kinds of loads and sources, which makes them prone to failure.
Bing Han, Yonggang Li
doaj +2 more sources
An Analytical Short-Circuit Current Calculation Method for Full-Power Wind Turbines under Complete Fault Ride-Through Processes [PDF]
Accurate calculation of short-circuit current throughout the fault ride-through process of wind turbines is a critical prerequisite for the analysis and control of modern power systems.
YUAN Shuai, XIAO Jiaan, TAO Jun, CUI Haohan, CHAO Pupu, LI Weixing, A Minfu, WANG Liqiang, ZHONG Ming
doaj +2 more sources
Hierarchical control-based fault ride-through of VSC-HVDC considering impacts of renewable energy
When a short-circuit fault occurs at the receiving-end grid, the unbalanced power in voltage source converter based high voltage direct current (VSC-HVDC) should be consumed to prevent excessive DC voltage rise, thereby enabling fault ride-through ...
Jinxin Ouyang, Fan Mo, Jiyu Chen
doaj +2 more sources
Coordinate Fault Ride-Through Strategy for Connection of Offshore Wind Farms Using Voltage Source-Converter-Based High-Voltage Direct-Current Transmission under Single Polar Fault. [PDF]
In a system where wind farms are connected to the grid via a bipolar flexible DC transmission, the occurrence of a short-time fault at one of the poles results in the active power emitted by the wind farm being transmitted through the non-faulty pole ...
Zhou H, Ge S, Qin L.
europepmc +2 more sources
Fault Ride-Through Study of Wind Turbines
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed.
Xinyan Zhang +3 more