Results 21 to 30 of about 5,122 (298)

Advanced Fault Ride-Through Strategy by an MMC HVDC Transmission for Off-Shore Wind Farm Interconnection

open access: yesApplied Sciences, 2019
In order to solve the problems brought upon by off-shore wind-power plants, it is important to improve fault ride-through capability when an on-shore fault occurs in order to prevent DC overvoltage.
Junghun Lee   +3 more
doaj   +2 more sources

Coordinated Control Strategy of DC Fault Ride-through for the WF Connected to the Grid Through the MMC-HVDC

open access: yesFrontiers in Energy Research, 2021
Aiming at the problems of DC fault isolation and power surplus in the HVDC system with large-scale wind farm (WF) integration after single-pole grounding fault, this article designs a modified current transfer modular multilevel converter (M-CT-MMC ...
Bo Zhu   +5 more
doaj   +1 more source

DC fault ride through of multilevel converters [PDF]

open access: yes2016 IEEE Energy Conversion Congress and Exposition (ECCE), 2016
Modular Multilevel Converters (MMC) can provide significant advantages for power transmission applications, however there are remaining challenges trading off DC fault response, losses and controllability. Alternative multilevel converter topologies using combinations of full bridge and half bridge submodules or series switches allow for competitive ...
Geraint Chaffey   +4 more
openaire   +1 more source

Fault ride‐through strategy for hybrid HVDC with cascaded multi‐infeed MMC inverters

open access: yesElectronics Letters, 2021
The hybrid HVDC with cascaded multi‐infeed MMC inverters suffers from the fragile characteristic of its MMC inverters and is easy to be over current and over voltage.
Jingbo Zhao   +4 more
doaj   +1 more source

DC Fault Ride Through Coordinated Control of Wind Power Flexible Direct Grid Connection Based on Decentralized Energy Storage

open access: yes工程科学与技术, 2023
Modular multilevel converter based high voltage direct current technology (MMC–MTDC) using overhead lines is an effective solution to solve the grid connected consumption of high proportion and long-distance renewable energy.
Yinfeng SUN   +5 more
doaj  

Control Strategy for Potential Vector Remolding Fault Ride-through in Grid-forming MMC [PDF]

open access: yesDianli jianshe
[Objective] The operational characteristics of the grid-forming modular multilevel converter (MMC) in offshore wind power transmission systems under short-circuit faults in the receiving-end grid are unclear, and the interaction mechanism between fault ...
FANG Chaoxiong, TANG Yuchen, LIN Yi, SHEN Hao, PAN Chao, BIAN Xiaoyan, ZHAO Jinbin
doaj   +1 more source

A Novel Control Strategy for AC Fault Ride Through in Multi-terminal DC System

open access: yes发电技术, 2022
This paper proposed a novel control strategy-coordinated DC voltage control (DCVC)-to enhance the AC fault ride through capability of multi-terminal high voltage direct current (HVDC) system.
YANG Zhou   +3 more
doaj   +1 more source

A DC Short-Circuit Fault Ride Through Strategy of MMC-HVDC Based on the Cascaded Star Converter

open access: yesEnergies, 2018
A modular multilevel converter based high voltage direct current (MMC-HVDC) with DC fault self-clearing is adopted to deal with the DC short-circuit fault.
Yingjie Wang   +4 more
doaj   +1 more source

Probabilistic Short-Circuit Current in Active Distribution Networks Considering Low Voltage Ride-Through of Photovoltaic Generation

open access: yesIEEE Access, 2019
The probabilistic short-circuit current (PSCC) of photovoltaic generation is determined by the voltage sag at the grid connection and the low voltage ride-through of the unit during the grid fault, while the voltage sag and the low voltage ride-through ...
Weiyan Qian   +5 more
doaj   +1 more source

LVRT Impact on Tower Loads, Drivetrain Torque and Rotational Speed—Measurement Results of a 2-MW Class DFIG Wind Turbine

open access: yesEnergies, 2021
With an increasing share in energy production, wind turbines have to fulfill strict grid requirements to support the grid in case of discontinuities. Here LVRT (Low Voltage Ride Through) compliance is one essential part, where the turbine has to stay ...
Mathias Arbeiter   +2 more
doaj   +1 more source