Results 21 to 30 of about 15,904,812 (239)
Control Strategy for Potential Vector Remolding Fault Ride-through in Grid-forming MMC [PDF]
[Objective] The operational characteristics of the grid-forming modular multilevel converter (MMC) in offshore wind power transmission systems under short-circuit faults in the receiving-end grid are unclear, and the interaction mechanism between fault ...
FANG Chaoxiong, TANG Yuchen, LIN Yi, SHEN Hao, PAN Chao, BIAN Xiaoyan, ZHAO Jinbin
doaj +1 more source
Fault ride-through enhancement of PMSG wind turbines with DC microgrids using resistive-type SFCL [PDF]
Integrating permanent magnet synchronous generator (PMSG) wind turbines with DC microgrids have attracted a great attention due to the inherent merits of DC systems. However, under the fault conditions, the excessive energy during fault will be reflected
Yuan, Weijia +2 more
core +2 more sources
Simplified Model For Simulation of Fault Ride Through at Hydropower Units
As new requirements for grid connected generators were implemented, the requirements for evaluating the Fault Ride Through capabilities of the generators became stricter.
Söderström, Sebastian
core +2 more sources
A DC Short-Circuit Fault Ride Through Strategy of MMC-HVDC Based on the Cascaded Star Converter
A modular multilevel converter based high voltage direct current (MMC-HVDC) with DC fault self-clearing is adopted to deal with the DC short-circuit fault.
Yingjie Wang +4 more
doaj +1 more source
The probabilistic short-circuit current (PSCC) of photovoltaic generation is determined by the voltage sag at the grid connection and the low voltage ride-through of the unit during the grid fault, while the voltage sag and the low voltage ride-through ...
Weiyan Qian +5 more
doaj +1 more source
With an increasing share in energy production, wind turbines have to fulfill strict grid requirements to support the grid in case of discontinuities. Here LVRT (Low Voltage Ride Through) compliance is one essential part, where the turbine has to stay ...
Mathias Arbeiter +2 more
doaj +1 more source
The low voltage direct current (LVDC) distribution networks are connected with too many kinds of loads and sources, which makes them prone to failure.
Bing Han, Yonggang Li
doaj +1 more source
A Novel Control Strategy for AC Fault Ride Through in Multi-terminal DC System
This paper proposed a novel control strategy-coordinated DC voltage control (DCVC)-to enhance the AC fault ride through capability of multi-terminal high voltage direct current (HVDC) system.
YANG Zhou +3 more
doaj +1 more source
The advantages, such as the mature control method, less volume of the converter and generator, make the doubly fed induction generator system prevalent in the wind power industry.
Zakiud Din +4 more
doaj +1 more source
A Hybrid HVDC Topology Suitable for Large-Scale Pure Clean Energy Power Base Transmission
In order to meet the transmission needs of large-scale pure new energy power bases, after topology comparison, this paper used a hybrid cascaded topology consisting of a line commutated converter (LCC) and a modular multilevel converter (MMC) in the ...
Wenzhe XU, Zheren ZHANG, Zheng XU
doaj +1 more source