Results 11 to 20 of about 3,787 (252)
This study proposes a high-temperature superconducting (HTS) bandpass filter with a continuously tunable bandwidth and center frequency. The proposed filter combines several gallium arsenide varactors and a dual-mode resonator (DMR).
Zhaojiang Shang +3 more
doaj +1 more source
Summary This article presents a complete design procedure for planar slotted waveguide antennas (SWA). For a desired sidelobe level ratio (SLR), the proposed method provides a pencil shape pattern with a narrow half power beamwidth, which makes the ...
Hilal M. El Misilmani +2 more
doaj +1 more source
With the rapid increase of distributed photovoltaic (PV) power integrating into the distribution network (DN), the critical issues such as PV power curtailment and low equipment utilization rate have been caused by PV power fluctuations.
Jian Xu +7 more
doaj +1 more source
Reliability 'H' scheme of HV/MV substations [PDF]
Substations (HV/MV) connect transmission and distribution systems with consumers of electric energy. The selective search method was used for calculation of substation reliability, where all arrangement elements were grouped into blocks.
Perić Dragoslav M. +3 more
doaj +1 more source
Method for LV Distribution Network Topology Verification Based on AMI Metering Data
Aiming at the problem of topology error identification in low voltage distribution network, a method is proposed for low voltage (LV) distribution network topology verification based on AMI metering data.
Weiguo YAN +5 more
doaj +1 more source
The Ferranti effect could cause a rise in voltage along the cables on a wind farm if the circuit breakers at the receiving ends are switched off. Ferroresonance could also occur due to stuck pole(s) of the circuit breaker during de-energization.
Ajibola Akinrinde +2 more
doaj +1 more source
Protection of Sensitive Loads in Distribution Systems Using a BSFCL-DVR System
In this paper, an incorporated bridge-type superconducting fault current limiter (BSFCL) and Dynamic Voltage Restorer (DVR) is presented to improve the voltage quality and limiting fault current problems in distribution systems. In order to achieve these
Mehdi Firouzi +4 more
doaj +1 more source
This work deals with decentralized optimization problems where a collection of network agents operate selfishly and individually under a set of coupling constraints among them.
Peng Wang, Suli Zou, Zhongjing Ma
doaj +1 more source
CONSIDERATIONS FOR THE DEVELOPMENT OF A DEVICE FOR THE DECOMMISSIONING OF THE HORIZONTAL FUEL CHANNELS IN THE CANDU 6 NUCLEAR REACTOR PART 4 - FUEL CHANNEL ASSEMBLY [PDF]
As many nuclear power plants are reaching their end of lifecycle, the decommissioning of these installations has become one of the 21st century’s great challenges. Each project may be managed differently, depending on the country, development policies,
Gabi ROSCA FARTAT +2 more
doaj
The paper designed a semicircle dipole inner sensor for UHF partial discharge detection in GIS. By comparing the symmetric semicircle dipole sensor and asymmetric semicircle dipole sensor characteristics, the symmetric semicircle dipole sensor’s coupling
Shi Wen +4 more
doaj +1 more source