Results 101 to 110 of about 8,849 (244)

Influence of Geometric Design on Mechanical Performance of Auxetic Metastructure

open access: yesAdvanced Engineering Materials, Volume 28, Issue 15, 5 August 2026.
Strategic geometric reinforcement transforms auxetic performance. This study evaluates 3D‐printed arrowhead metastructures, revealing that a modified design with local ring reinforcement suppresses premature failure to achieve superior energy absorption and structural efficiency.
Muhammad Gulzari   +3 more
wiley   +1 more source

Development and Characterization of ZnO‐Filled and Maleic Anhydride‐Compatibilized PP/SEBS Blends for 3D‐Printing Filaments

open access: yesJournal of Applied Polymer Science, Volume 143, Issue 29, August 5, 2026.
PP/SEBS/MA/ZnO filaments produced by bench‐top single‐screw extrusion show refined morphology, increased crystallinity, improved thermal robustness, and preliminary FFF printability, demonstrating a practical route for functional filament development. ABSTRACT Currently, single‐screw extrusion offers a versatile and accessible route to produce polymer ...
Chiara das Dores do Nascimento   +12 more
wiley   +1 more source

Application of an updated severity‐based FMEA approach to Radiation Therapy QA: A multi‐institutional exercise

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background External beam radiation therapy (RT) involves many complex steps to safely and reliably treat patients. The radiation oncology community has adopted process maps and failure modes and effects analysis (FMEA) to analyze risk using the TG‑100 methodology, but the traditional TG‑100–endorsed risk priority number (RPN) has recognized ...
Alejandra Rangel   +6 more
wiley   +1 more source

Commissioning and performance evaluations of the electron Monte Carlo algorithm in a new commercial treatment planning system

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Purpose This study provides a comprehensive evaluation of the newly implemented electron Monte Carlo dose calculation algorithm in the commercial treatment planning system, uTPS. It investigates the performance of the algorithm by examining its dosimetric accuracy and calculation speed, which have not been previously reported in the literature.
Feng Wang   +5 more
wiley   +1 more source

Accelerated and standardized commissioning of a robotic RadioSurgery system using a hybrid golden beam data model

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background The CyberKnife™ system requires extensive beam data acquisition across multiple collimation systems. The CyberComm™ framework integrates a linac output tuning procedure with a hybrid Golden Beam Data (GBD) model to accelerate and standardize CyberKnife commissioning while maintaining dosimetric accuracy.
E. Pantelis   +4 more
wiley   +1 more source

Dosimetric correlation between exit dose maps and anatomical changes in head and neck cancer treatment on Halcyon‐E: A gamma analysis approach

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Head and neck cancer (HNC) has a high incidence in Brazil. Although Image‐Guided Radiation Therapy (IGRT) improves treatment precision, anatomical changes during the treatment course may compromise dose distribution and require replanning.
Jayane Julia Pereira da Silva   +6 more
wiley   +1 more source

A geometry‐based scaling model for stereotactic treatment volume definition in stereotactic centralized ablative radiation therapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Stereotactic Centralized Ablative Radiation Therapy (SCART) is a spatially fractionated radiotherapy strategy designed for large or bulky tumors by delivering an intensified ablative dose to a centrally located subvolume while allowing controlled dose reduction toward the tumor periphery.
Ningjing Siah   +6 more
wiley   +1 more source

Dosimetric and clinical validation of a high‐density bolus for superficial skin tumors treated with radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Accurate dose deposition in superficial radiotherapy remains challenging due to the inherent skin‐sparing effect of megavoltage photon beams and difficulties in ensuring bolus conformity. Purpose This study aims to comprehensively evaluate the dosimetric characteristics of the room‐temperature‐malleable high‐density bolus, to ...
Jonathan Dadoun   +15 more
wiley   +1 more source

Performance evaluation of a new type of commercial silicon detectors for photon beam dosimetry

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Modern radiotherapy relies on advanced treatment techniques that utilize a large number of small fields, for which maintaining dosimetric accuracy is often challenging. Most vendors have introduced microdetectors suitable for small field dosimetry. Sun Nuclear has developed two silicon diodes with a sensitive volume of 0.35 mm3 that
Indra J. Das   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy