Results 111 to 120 of about 8,849 (244)

Assessment of 6MV flattening filter free (FFF) beam commissioning parameters for Versa HD and TrueBeam: A comparison study

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Flattening filter‐free (FFF) beams are increasingly deployed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS). The Elekta Versa HD (VHD) and Varian TrueBeam (TB) are the two most widely used FFF‐capable platforms; however, no prior study has compared their 6 MV FFF commissioning parameters under fully ...
Mustafa K. Al‐Aseebee   +2 more
wiley   +1 more source

Monte carlo assessment of advanced shielding materials for space‐efficient radiotherapy vault design

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Conventional radiotherapy vault shielding typically employs 2 to 3 meters of ordinary concrete, consistent with NCRP Report 151 reference data. While NCRP 151 specifies dose‐based design goals rather than mandating particular materials, the practical default of concrete results in vault footprints of 150 to 200 m2 per linac, which ...
Beechui Koo   +6 more
wiley   +1 more source

Clinical implementation and performance evaluation of a motorized MR‐compatible OCTAVIUS 4D system for SBRT patient‐specific QA on a 1.5 T MR‐LINAC

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Magnetic resonance–guided radiotherapy using 1.5 T MR‐LINAC systems introduces specific constraints for patient‐specific quality assurance (PSQA), requiring MR‐compatible dosimetric devices capable of accurate three‐dimensional dose verification.
Clement Chevillard   +5 more
wiley   +1 more source

Systematic review of physical and dosimetric criteria for managing CIEDs in radiotherapy: A medical physicist's perspective

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Aim Current radiotherapy (RT) guidelines for Cardiac Implantable Electronic Devices (CIEDs) are largely based on clinical management strategies and retrospective reports. This systematic review adopts a medical physics perspective to provide a critical, quantitative analysis of the technical evidence required for developing robust safety ...
Tiziana Malatesta   +15 more
wiley   +1 more source

Free Fibula Flap Arthrodesis After En Bloc Resection of Distal Radius Giant Cell Tumors: Functional and Oncologic Outcomes From a Single-institution Experience. [PDF]

open access: yesPlast Reconstr Surg Glob Open
Abdel Al S   +10 more
europepmc   +1 more source

A dosimetric study of photon energy and flattening filter mode combinations in Stereotactic Central Ablative Radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background In Stereotactic Central Ablative Radiotherapy (SCART), the volume of tumor receiving the full prescribed ablative dose decreases rapidly as the prescription dose increases, posing a critical challenge. To address this issue, this study investigates the dosimetric impact of combining various photon energies and flattening filter ...
Jianwei Sun   +5 more
wiley   +1 more source

Tough, Ductile, and Strong Hard‐Soft Cementitious Composite Enabled by Multi‐Material Additive Manufacturing

open access: yesAdvanced Materials, Volume 38, Issue 45, 13 August 2026.
Drawing inspiration from the layered hard‐soft architecture found in sea sponges, this work establishes a new framework for architected cementitious composites (ACC) through multi‐material additive manufacturing (MMAM) process. The integration of mortar and elastomer phases into layered architectures enables synergistic toughening mechanisms, including
Aimane Najmeddine   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy