Results 131 to 140 of about 10,619 (226)
Abstract Background Treatment planning systems (TPSs) are essential in modern radiotherapy. Accurate beam modeling, especially of multileaf collimators (MLCs), is crucial, as their complex designs often introduce systematic uncertainties in planned and delivered doses.
Fasco van Ommen +6 more
wiley +1 more source
Additive Manufacturing of Polymer-Based Composites Using Fused Filament Fabrication (FFF): a Review
M. Ahmadifar +3 more
semanticscholar +1 more source
Comparison of two close‐packing methods for vertex placement in lattice radiotherapy (LRT)
Abstract Background Lattice Radiation Therapy (LRT) is characterized by its 3D‐mouldated spatial dose distribution of vertices inside the lattice volume with high peak‐to‐valley dose ratio (PVDR) for enhancing tumor control and reducing normal tissue toxicity.
Yingjie Song, Pan Ma, Jianrong Dai
wiley +1 more source
Abstract Purpose This study compares stereotactic radiosurgery (SRS) treatment plan quality between the recently launched ZAP‐Axon® Krylov optimizer and the Leksell Gamma Knife® (LGK) Lightning optimizer for brain metastasis (BM). Methods Thirty (n = 30) patients who were previously treated with LGK SRS or fractionated SRS were selected and divided ...
Yongsook C. Lee +8 more
wiley +1 more source
Abstract Purpose/Objective We report our institutional clinical experience of treatment planning, dose evaluation, and delivery via the same‐day 3D MLC‐based crossfire method for spatially fractionated radiotherapy (SFRT) in conjunction with combination therapy. Additionally, we aimed to model our clinical outcome data to provide clinical insights into
Joshua Misa +3 more
wiley +1 more source
Abstract Background Varian machine performance check (MPC) is a manufacturer integrated quality control system included as standard for TrueBeam and Halcyon linear accelerators (linacs) to assess performance using a broad range of geometric and beam tests.
Lauren May +12 more
wiley +1 more source
Abstract Background Online adaptive radiotherapy (oART) accounts for anatomical changes by adjusting treatment plans on a daily basis. However, comprehensive plan‐specific quality assurance (QA) is challenging, as pre‐treatment measurements cannot be performed with the patient on the treatment couch.
Julian Niedling +4 more
wiley +1 more source
Abstract Background Automated radiotherapy treatment planning has benefited from data‐driven approaches; however, achieving consistently high plan quality across patients remains challenging. Dose prediction models provide patient‐specific priors but lack adaptive optimization, whereas large language models (LLMs) offer strong reasoning capabilities ...
Heling Zhu +7 more
wiley +1 more source
Seamless Mechanical Programming Through Hybrid Epoxy–Acrylate Printing for Soft–Rigid Robots
Hybrid epoxy‐acrylate printing enables seamless fabrication of soft–rigid robotic systems with covalently integrated interfaces and functionally graded mechanics. Grayscale exposure expands the accessible material space, enabling spatially programmed actuation through patterned stiffness while revealing the mechanics and durability of continuously ...
David C. Bershadsky +3 more
wiley +1 more source
ABSTRACT This paper presents a transferable computer‐aided engineering educational framework for teaching topology optimization through polymer material extrusion prototyping and numerical‐experimental validation. The framework is intended to help students move from idealized numerical simulation toward design decisions constrained by manufacturability,
Natalia García‐Fernández +4 more
wiley +1 more source

