Results 51 to 60 of about 23,922 (257)
Monitoring contamination level on insulator materials under dry condition with a microwave reflectometer [PDF]
Current techniques used for monitoring the levels of contamination on high voltage insulators, such as leakage current and infrared, are not effective in dry conditions since they require the surface of the insulator to be wetted by fog, rain or snow. If
Jiang, Y. +5 more
core +1 more source
ABSTRACT Periodic lattice material (PLM) is an innovative material system capable of rapidly and efficiently constructing functionally graded materials (FGMs). Among various PLM structures, triply periodic minimal surfaces (TPMS) exhibit numerous advantages, making TPMS‐based lattice materials a potential candidate to electrical FGMs.
Zihao Liu +7 more
wiley +1 more source
Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC [PDF]
In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the ...
Ahmad, H. +6 more
core
Lightning strike is the main reason for the transmission line tripping. Studies on the insulator flashover characteristics and the accurate flashover criteria under the lightning impulse are the basis for correctly evaluating the lightning resistance ...
Yongxia Han +7 more
doaj +1 more source
ABSTRACT The surface charge accumulation on insulators is one of the important factors that limit the development of high‐voltage direct current (HVDC) gas insulated transmission line (GIL), and the accurate measurement of surface charge is the basis to explore its physical mechanism.
Lei Zhang +3 more
wiley +1 more source
Increased surface flashover voltage in microfabricated devices [PDF]
With the demand for improved performance in microfabricated devices, the necessity to apply greater electric fields and voltages becomes evident. When operating in vacuum, the voltage is typically limited by surface flashover forming along the surface of
Hensinger, W. K. +3 more
core +2 more sources
Surface flashover fault is one of the most challenge issues in oil-cellulose insulation pressboard system used in power transformer. In this study, a comparative study of the AC surface flashover properties of the novel 3-element mixed oil-cellulose ...
Xin Chen +5 more
doaj +1 more source
This paper informs on the flashover strength of three materials: Delrin (polyoxymethylene), HDPE (high-density polyethylene) and Ultem (polyetherimide) with smooth surface finishes, in zero-grade air at -0.5, 0 and 0.5 bar gauge, and at <; 10%, ~50 ...
Ruairidh W. Macpherson +4 more
doaj +1 more source
ABSTRACT The breakdown characteristics of the novel eco‐friendly insulating gas CF3SO2F are fundamental to the design of gas‐insulated equipment. In this paper, the gas mixture parameters for CF3SO2F were optimised for different ambient temperatures in order to ascertain the insulation performance and liquefaction temperature constraints.
Shubo Ren +5 more
wiley +1 more source
The synergistic effect of micro structure/nanofiller/superhydrophobicity on the surface flashover
The surface flashover is affected by many factors, such as surface roughness, nanofillers and chemical functional groups. In this research study, polyamide mesh was utilised as a scaffold to systematically study the synergistic effect of micro structure ...
Qing Xie +6 more
doaj +1 more source

