Results 61 to 70 of about 23,922 (257)
A suitable, non-standard method for artificial pollution testing using simulated acid rain pollution in a laboratory was developed in this work. The method is applicable to a wide range of climatic conditions and rain acidities.
Chibuike Ilomuanya +2 more
doaj +1 more source
Micro Partial Discharge Characteristics of SF6 Under DC Voltage
ABSTRACT In gas‐insulated high‐voltage direct current (HVDC) devices, micro partial discharges (PD) caused by micro‐protrusions or surface roughness on conductors or enclosures may not cause immediate insulation system failure due to their weak discharge intensity.
Geng Chen +4 more
wiley +1 more source
Arc tracking control in insulation systems for aeronautic applications: challenges, opportunities, and research needs [PDF]
Next generation aircrafts will use more electrical power to reduce weight, fuel consumption, system complexity and greenhouse gas emissions. However, new failure modes and challenges arise related to the required voltage increase and consequent rise of ...
Bogarra Rodríguez, Santiago +3 more
core +2 more sources
ABSTRACT Film capacitors, essential for energy storage in power systems, benefit from reduced film thickness to increase capacitance and lower costs. While the inverse power law traditionally links higher electric strength with thinner films, its validity diminishes below a critical thickness.
Chuansheng Zhang +5 more
wiley +1 more source
PCB layouts with different polygon shapes and insulation distances were prepared and their surface flashover voltage subjected to different ramping rates were measured at different temperatures and different low gas pressures for emulated high-altitude ...
Jierui Zhou +10 more
doaj +1 more source
Development of ± 550 kV DC GIS Basin Insulator
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao +9 more
wiley +1 more source
Prediction Flashover Voltage on Polluted Porcelain Insulator Using ANN
: This paper aims to assess the effect of dry band location of contaminated porcelain insulators under various flashover voltages due to humidity.
A. Salem +4 more
semanticscholar +1 more source
Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects
ABSTRACT The safe and stable working of dry‐type valve‐side bushings, important components of converter transformers, is essential. In recent years, poor design has led to several core breakdown, flashover and cracking failures. The bushing cores, composed of crepe paper and aluminium foil, exhibit significant anisotropic physical properties due to its
Gaoyi Shang +6 more
wiley +1 more source
Field Analysis of SF(6) Gas Insulated Cables and Its Application to Spacer Design [PDF]
This paper describes the spacer design for SF(6) gas insulated cables. The maximum electric stress within the cable is calculated by a numerical method, and it is recognized that the breakdown voltage depends linearly on the calculated values.
Itaka, Koshi +2 more
core +1 more source
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of composite crossarm insulators under different voltage grades.
J. Nan +4 more
semanticscholar +1 more source

