Results 61 to 70 of about 6,201 (230)

Flashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower

open access: yesEnergies, 2018
The flashover performance of insulators is the foundation of the calculation of precise lightning protection. The material and structure of an insulator affect its flashover performance but the research on the differences in the flashover performance of ...
Yaqi Zhang   +9 more
doaj   +1 more source

Failure behavior of dielectric films for peaking capacitor subjected to surface flashover under nanosecond pulses

open access: yesAIP Advances, 2023
The flashover failure and damage of polypropylene (PP) and polyester (PET) films under nanosecond current pulses were experimentally investigated.
Zhiqiang Chen   +8 more
doaj   +1 more source

Study of Positive Corona Discharge of Needle Plate Electrodes in Airflow

open access: yesHigh Voltage, EarlyView.
ABSTRACT For high‐speed moving objects such as aircraft and wind turbine blades, discharge occurs under strong airflow. Research on lightning attachment characteristics has been extensive, whereas the role of corona discharge in pre‐breakdown streamer development has received less attention.
Lei Lan   +6 more
wiley   +1 more source

Research on Hot-line Cleaning of Artificial Contaminanted Insulator Using High Pressure Hot Water Vapor

open access: yesGaoya dianqi, 2014
The hot-line cleaning of insulator contaminants has a great significance to prevent pollution flashover.The technique of hot-line cleaning insulator contaminants by water vapor is proposed in this paper.The flashover characteristics of insulator under ...
LE Zhenchun   +4 more
doaj  

Tower grounding improvement versus line surge arresters: comparison of remedial measures for high-BFOR subtransmission lines [PDF]

open access: yes, 2015
This paper presents a technical/economic comparison between remedial measures aimed at improving the lightning performance of an existing Italian three-phase 150-kV overhead line.
GATTA, Fabio Massimo   +4 more
core   +1 more source

Landscape, stand and tree characteristics influence the distribution of lightning damage in Central African forests

open access: yesFunctional Ecology, EarlyView.
Read the free Plain Language Summary for this article on the Journal blog. Abstract The impact of lightning in tropical forests remains uncertain. Specifically, the factors that influence the spatial distribution of lightning damage within forests remain unknown.
Bianca Zoletto   +14 more
wiley   +1 more source

Review of Treatments for Suppressing Surface Charge Accumulation and Enhancing Surface Flashover Voltage

open access: yesCSEE Journal of Power and Energy Systems
The focus of this paper is to provide a comprehensive review of various insulation performance improvement methods for vacuum-solid and compressed air-solid interfaces.
Jixing Sun   +9 more
doaj   +1 more source

Luminescence evolution from alumina ceramic surface before flashover under direct and alternating current voltage in vacuum

open access: yesAIP Advances, 2016
The luminescence evolution phenomena from alumina ceramic surface in vacuum under high voltage of direct and alternating current are reported, with the voltage covering a large range from far below to close to the flashover voltage. Its time resolved and
Guo-Qiang Su   +6 more
doaj   +1 more source

Series Connection of LCC and Full Bridge MMC With DC Fault Ride‐Through Capability for Lightweight HVDC Transmission

open access: yesEngineering Reports, Volume 8, Issue 4, April 2026.
In this work, we investigate a lightweight HVDC converter topology that combines the strengths of line‐commutated converters (LCC) and full‐bridge modular multilevel converters (MMC) to address the high cost and large footprint of conventional HVDC stations.
Yang Wang   +7 more
wiley   +1 more source

Effects of surface roughness on DC and AC surface flashover performances of epoxy composites in SF6/N2 mixtures [PDF]

open access: yesAIP Advances
Surface flashover of the epoxy insulator is one of the urgent insulation issues in SF6/N2 filled gas-insulated equipment, causing irreversible insulation failure and harming the secure operation of power systems. However, the effects of surface roughness,
Lei Zhang   +9 more
doaj   +1 more source

Home - About - Disclaimer - Privacy