Results 41 to 50 of about 772,396 (130)
The present study aimed to develop the electrical performance of outdoor insulators using a nano-TiO2 coating for railway electrification systems. The prototype design of porcelain insulators with normal coatings and using a nano-TiO2 coating is based on
Pichai Muangpratoom +2 more
doaj +1 more source
Effecft of co‐doping polyaniline with phosphoric acid and phytic acid on the heat release rate of polyethylene. Abstract Polyolefins, such as polyethylene (PE), are highly flammable and electrically insulative, limiting their applicability. The study explored the flame‐retardancy and electrical conductivity of PE/polyaniline (PE/PANI) nanocomposites ...
Akeem Adisa +4 more
wiley +1 more source
ABSTRAK Penelitian ini bertujuan untuk mengetahui seberapa besar nilai coating isolator yang dapat ditembus listrik berdasarkan Basic Insulator Level (BIL).
YUSRENI WARMI, KAZNI FEBRIAN
doaj +1 more source
Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li +9 more
wiley +1 more source
Effect of inverted T arrangement on AC pollution flashover characteristics of insulator strings
The arrangement of insulator strings has an effect on its pollution flashover characteristics. A new arrangement of insulator strings, inverted T-type arrangement, is proposed in this study.
Xingliang Jiang +6 more
doaj +1 more source
In recent years, the electrical performance of polluted suspension insulators operating in coastal foggy regions has attracted wide attention because of the occurrence of flashover. Surface wetting by salt fog accretion increases the surface conductivity
Bingbing Dong +5 more
doaj +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
AC pre-discharge currents, breakdown, and flashover voltage measurements are reported in a 10 mm needle-plane arrangement in a 4% NovecTM 4710/96% CO2 gas mixture and compared with CO2 for pressures up to 8.8 bar abs.
Houssem Eddine Nechmi +3 more
doaj +1 more source
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng +8 more
wiley +1 more source
Modeling of High Voltage Pollution Discharge to Investigate Hot Stick Flashover [PDF]
Electric “flashover” or insulation breakdown has occurred on “hot stick” safety tools used on live AC transmission lines at Manitoba Hydro in 1997 and 2002.
Reske, Dean
core