Results 31 to 40 of about 732,564 (210)
In the direct current electric field, the surface of epoxy resin (EP) insulating material is prone to charge accumulation, which leads to electric field distortion and damages the overall insulation of the equipment. Nano-doping is an effective method to
Jun Xie +5 more
doaj +1 more source
Laboratory investigation of insulator contamination problems [PDF]
Includes bibliographical references.This thesis deals with the practical aspect of the laboratory examination of contaminated insulators. A technique which gives a pollution curve for cylindrical insulator models is described.
Travaglini, Mario
core +1 more source
PCB layouts with different polygon shapes and insulation distances were prepared and their surface flashover voltage subjected to different ramping rates were measured at different temperatures and different low gas pressures for emulated high-altitude ...
Jierui Zhou +10 more
doaj +1 more source
Electrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion [PDF]
In order to study the flashover mechanism of polluted insulators under AC voltage, a new arc propagation criterion which is based on an arc root voltage gradient is proposed.
Qing Yang +11 more
core +1 more source
Development of Flame Retarded Battery Casings Using Glass Fiber‐Reinforced Epoxy Resin
Development of flame retarded battery casings using glass fiber‐reinforced epoxy resin by exploiting the synergistic action of APP and TiO2 to promote the formation of a coherent ceramic‐phosphate char layer. ABSTRACT This study investigates the development of glass fiber‐reinforced epoxy resin composites with enhanced fire performance for application ...
Ákos Pomázi +4 more
wiley +1 more source
Surface flashover fault is one of the most challenge issues in oil-cellulose insulation pressboard system used in power transformer. In this study, a comparative study of the AC surface flashover properties of the novel 3-element mixed oil-cellulose ...
Xin Chen +5 more
doaj +1 more source
Fire Testing and Hazard Assessment for Flame Retardant Polymer Composites
Flame retardant polymer composites are now being evaluated with more than pass or fail flammability tests. Heat release, smoke, toxicity, and system‐level behavior are receiving more attention, and multi‐scale methods are being used to describe fire hazard under more realistic conditions.
Shuheng Wang +8 more
wiley +1 more source
Introduction. Polyester-based composites are increasingly used in electrical applications for their insulation, mechanical, and thermal properties. Nanofillers have shown promise in enhancing the properties of polymer-based composites. Goal.
M. Rihan +4 more
doaj +1 more source
Under dc electric field, pollution may be more easily deposited around insulator string caps and pins, distributing non-uniformly on its inner and outer parts, and presenting ring-like shape.
Zhijin Zhang +6 more
doaj +1 more source
Improvement of surface flashover in vacuum
Surface flashover of insulation systems is a basic issue in the field of high voltage and electrical insulation. To improve the surface flashover performance is of great significance for the development of advanced power transmission equipment and ...
Shengtao Li
doaj +1 more source