Results 11 to 20 of about 720,455 (297)

Assessment of Treatment Plan Quality between Flattening Filter and Flattening Filter Free Photon Beam for Carcinoma of the Esophagus with IMRT Technique [PDF]

open access: yesJournal of Biomedical Physics and Engineering, 2023
Background: As compared to the flattened photon beam, removing the flattening filter (FF) from the head of a gantry decreases the average energy of the photon beam and increases the dose rate, leading to an impact on the quality of treatment plans ...
Dinesh Kumar Saroj   +5 more
doaj   +4 more sources

Comparative investigation of beam quality index Q on flattening filter and flattening filter free 6 and 15 MV photon beams of an medical linear accelerator [PDF]

open access: yesCurrent Directions in Biomedical Engineering, 2017
An Elekta Synergy LINAC was used to investigate the beam quality index Q and the beam quality correction factor kQ, which is used for absolute dosimetry, in off-axis photon fields.
Schaks Michael   +5 more
doaj   +4 more sources

Comparative dosimetric analysis of flattening-filter and flattening-filter-free photon beams in radiotherapy based on TRS-398 calibration protocol [PDF]

open access: goldReports of Practical Oncology and Radiotherapy
BACKGROUND: In external beam radiotherapy, delivering an accurate radiation dose is essential to ensure treatment effectiveness while minimising harm to surrounding healthy tissue.
Sakinah Sakinah   +3 more
doaj   +4 more sources

Comparative analysis of melatonin’s protective role against flattening filter and flattening filter-free X-ray induced nephropathy: focus on apoptosis and SIRT1 modulation [PDF]

open access: goldBMC Nephrology
Background Radiation-induced nephropathy is a major concern, particularly for patients undergoing radiotherapy. This study investigates melatonin’s (MEL) protective effects against kidney damage induced by Flattening Filter (low dose rate-LDR) and ...
Kübra Şevgin   +5 more
doaj   +3 more sources

Dosimetric comparison of unmatched flattening filter-free and flattened beams in volumetric arc therapy plans for head-and-neck cancer [PDF]

open access: yesJournal of Medical Physics, 2023
Introduction: Conventionally, the fattened beam is being used in radiotherapy for routine clinical cases even after introduction of intensity-modulated radiotherapy with incorporation of multi-leaf collimator system.
Arvind Kumar   +3 more
doaj   +2 more sources

Contrast Enhancement for Portal Imaging in Nanoparticle-Enhanced Radiotherapy: A Monte Carlo Phantom Evaluation Using Flattening-Filter-Free Photon Beams [PDF]

open access: yesNanomaterials, 2019
Our team evaluated contrast enhancement for portal imaging using Monte Carlo simulation in nanoparticle-enhanced radiotherapy. Dependencies of percentage contrast enhancement on flattening-filter (FF) and flattening-filter-free (FFF) photon beams were ...
Aniza Abdulle, James C. L. Chow
doaj   +2 more sources

Analysis of Volumetric Modulated Arc Therapy for Large Planning Target Volumes in Rectal Cancer: Flattening Filter-free Halcyon System versus Flattened Filter Clinac iX [PDF]

open access: diamondJournal of Medical Physics
This study presents a comparative dosimetric and efficiency analysis of volumetric modulated arc therapy (VMAT) for large planning target volumes (PTVs) (≥1000 cm³), contrasting plans from a flattening filter-free (FFF) Halcyon system with a conventional
Hyeonu Kim
doaj   +4 more sources

Dosimetric and Radiobiological Impact of Flattening Filter‐Free Beam and Dose Calculation Algorithm Using RapidArc Plans for Cervical Cancer Treatment [PDF]

open access: yesPrecision Radiation Oncology, 2023
Purpose The aim of this study is to quantify the potential benefits of a flattening filter‐free (FFF) beam and implement a dose‐computation algorithm for cervical radiotherapy through dosimetric and radiobiological analyses using RapidArc. Methods Thirty‐
Sumanta Manna   +3 more
doaj   +2 more sources

Comparison Flattening Filter and Flattening Filter-Free Techniques in Small-Fields Dosimetry with Various Types of Detectors [PDF]

open access: yesAsian Pacific Journal of Cancer Prevention
The aim of this study was to investigate the detector size effect on small-field dosimetry and compare the performance of 6MV WFF/FFF techniques.We investigated the detector size effect on small-field dosimetry and compared the performance of 6MV WFF/FFF techniques.
Alashkar, Elsayed M.   +5 more
openaire   +3 more sources

Dose to contralateral breast from whole breast irradiation by automated tangential IMRT planning: comparison of flattening-filter and flattening-filter-free modes [PDF]

open access: yesRep Pract Oncol Radiother, 2022
Background: The most common secondary cancer is contralateral breast (CLB) cancer after whole breast irradiation (WBI). The aim of this study was to quantify the reduction of CLB dose in tangential intensity modulated radiotherapy (t-IMRT) for WBI using ...
Shigenaga, Daisuke; Department of Radiation Oncology, Yokohama City University Medical Center, Yokohama, Japan   +7 more
core   +2 more sources