Results 21 to 30 of about 720,455 (297)

Commissioning Measurements of Flattening Filter and Flattening Filter Free Photon Beams Using a TrueBeam Stx® Linear Accelerator [PDF]

open access: yesIranian Journal of Medical Physics, 2019
Introduction: TrueBeam STx® latest generation linear accelerators (linacs) were installed at Sheikh Khalifa International University Hospital Casablanca, Morocco, this study aimed to present and analyse the dosimetric characteristics obtained during the commissioning.
SAIDI, Kamal   +3 more
openaire   +2 more sources

Stereotactic Radiotherapy for Non-small Cell Lung Cancer with Small Lesions
Applying A Flattening Filter Free Clinac

open access: yesChinese Journal of Lung Cancer, 2015
Background and objective With the rapid development of technology, stereotactic radiotherapy has been widely used. In a cohort of medically operable non-small cell lung cancer patients receiving stereotactic body radiation therapy (SBRT) survival rates ...
Jianhao GENG   +4 more
doaj   +2 more sources

Evaluation of Ion Recombination Correction for Indigenously Developed Farmer Ion Chamber in Flattening Filter-Free Photon Beams [PDF]

open access: yesJournal of Medical Physics
Purpose and Aim: Modern generation linear accelerator (linac) either generates X-rays with a flattening filter (WFF beam) or without flattening filter free (FFF beam).
Parimal T. Patwe   +2 more
doaj   +2 more sources

Validation of an EGSnrc Monte Carlo Model of a 10 MV Photon Beam for Varian Clinac iX Linac, Including Flattening and Flattening-Free Modes

open access: yesQuantum Beam Science
Modelling of linear accelerators using the Monte Carlo method is critical for precise radiotherapy planning. In addition, detailed and accurate dose estimation to the organ at risk can be assessed and optimized. In this study, EGSnrc Monte Carlo code was
Wafa M. Al-Saleh
doaj   +2 more sources

Evaluating Mobius3D Dose Calculation Accuracy for Small-Field Flattening- Filter-Free Photon Beams [PDF]

open access: yesTechnology in Cancer Research & Treatment, 2022
Purpose: We aimed to investigate the dose calculation accuracy of Mobius3D for small-field flattening-filter-free x-rays, mainly utilized for stereotactic body radiation therapy (SBRT).
Changhwan Kim PhD   +6 more
doaj   +2 more sources

The effect of prostate motion during hypofractionated radiotherapy can be reduced by using flattening filter free beams

open access: yesPhysics and Imaging in Radiation Oncology, 2018
Background and purpose: Hypofractionated radiotherapy of prostate cancer reduces the overall treatment time but increases the per-fraction beam-on time due to the higher fraction doses.
Hunor Benedek   +5 more
doaj   +2 more sources

Depth Dose Enhancement on Flattening-Filter-Free Photon Beam: A Monte Carlo Study in Nanoparticle-Enhanced Radiotherapy

open access: yesApplied Sciences, 2020
The aim of this study is to investigate the variations of depth dose enhancement (DDE) on different nanoparticle (NP) variables, when using the flattening-filter-free (FFF) photon beam in nanoparticle-enhanced radiotherapy. Monte Carlo simulation under a
James C. L. Chow
doaj   +2 more sources