Optimization of the calculation time in simulation using the GATE/GEANT4 Monte Carlo of radiotherapy treatment plans for small fields [PDF]
Radiation therapy is one of the most widely used methods of treating cancer. One of the therapeutic gains of this method is to save in terms of calculation time during treatment planning, the variance reduction method is one of the most used to reduce ...
Tantaoui Meriem +6 more
doaj +1 more source
Dose-volume histograms (DVHs) of the flattening filter-free intensity-modulated radiotherapy (FFF-IMRT), conventional IMRT (C-IMRT), flattening filter-free volumetric modulated arc therapy (FFF-VMAT) and conventional VMAT (C-VMAT) plans for Patient 4. [PDF]
Dose-volume histograms (DVHs) of the flattening filter-free intensity-modulated radiotherapy (FFF-IMRT), conventional IMRT (C-IMRT), flattening filter-free volumetric modulated arc therapy (FFF-VMAT) and conventional VMAT (C-VMAT) plans for Patient 4.
Jing Zheng (65946) +3 more
core +1 more source
Dose distributions of the flattening filter-free intensity-modulated radiotherapy (FFF-IMRT), conventional IMRT (C-IMRT), flattening filter-free volumetric modulated arc therapy (FFF-VMAT) and conventional VMAT (C-VMAT) plans for Patient 4. [PDF]
Dose distributions of the flattening filter-free intensity-modulated radiotherapy (FFF-IMRT), conventional IMRT (C-IMRT), flattening filter-free volumetric modulated arc therapy (FFF-VMAT) and conventional VMAT (C-VMAT) plans for Patient 4.
Jing Zheng (65946) +3 more
core +1 more source
Design and analysis of a control system for an optical delay-line circuit used as reconfigurable gain equalizer [PDF]
The design and analysis of a control system for a coherent two-port lattice-form optical delay-line circuit used as reconfigurable gain equalizer is presented.
McBride, R. +4 more
core +1 more source
The Dosimetric Comparison of Different SBRT Techniques for Treatment of Liver Cancer Using Flattened and Flattening Filter Free Beam [PDF]
Introduction:To compare the three-dimensional conformal radiotherapy (3DCRT), dynamic conformal arc therapy (DCA), and volumetric modulated arc therapy (VMAT) in stereotactic body radiation therapy (SBRT) of liver cases using 6MV and 10 MV flattened beam
SURESH T, Saminathan MADESWARAN
doaj +1 more source
Comparison of treatment plan quality of VMAT for esophageal carcinoma with: flattening filter beam versus flattening filter free beam [PDF]
Purpose: To investigate the difference in treatment plan quality of volumetric modulated arc treatment (VMAT) for esophageal carcinoma with flattening filter beam (FF) and flattening filter free beam (FFF). Material and methods: A total of fifty-six treatment plans were generated for twenty eight esophageal carcinoma patients with flattening filter ...
Sun, Wen-zhao +5 more
openaire +2 more sources
A research on neutron contamination in LINAC device has been carried out using a Monte Carlo method. The simulation is based on the Siemens Primus LINAC machine model whose component consists of target, primary collimator, flattening filter and ...
Bilalodin Bilalodin +2 more
doaj +1 more source
Flattening Filter Free vs. Flattened Beams for Lung Stereotactic Body Radiation Therapy [PDF]
To assess the clinical impact of high dose rate stereotactic body radiation therapy (SBRT) in patients with lung neoplastic lesions.From January 2014 to June 2016, a single-center retrospective analysis was performed including all patients treated by either flattening filter free (FFF) beams or flattening filter beams (FF) three-dimensional (3D) SBRT ...
Pierre, Annede +15 more
openaire +2 more sources
Novità in Radioterapia: Flattening Filter Free [PDF]
Il Flattening Filter (FF), ossia il filtro di attenuazione, omogenizza energia ed intensità del fascio di Raggi X durante l'erogazione di un trattamento radioterapico.
Papaleo, Antonella +4 more
core +2 more sources
Structural shielding design of a 6 MV flattening filter free linear accelerator: Indian scenario
Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC) operated with flattening filter (FF) and flattening filter free (FFF) modes are calculated.
Bibekananda Mishra +2 more