Results 71 to 80 of about 6,634,558 (252)

An Experimental Study of the Effect of a Baffle on the Flow Structure in a Rectangular Open Channel Using UVP

open access: yesJournal of Fluid Science and Technology, 2010
A flow structure around an intermediate standing baffle in a rectangular open channel has been investigated experimentally. The instantaneous vertical velocity components were successfully measured using an Ultrasonic Velocity Profiler (UVP).
Hamidreza JAMSHIDNIA, Yasushi TAKEDA
doaj   +1 more source

Association Between Individualized Education for Kidney Replacement Therapy Modality Selection and Peritoneal Dialysis Initiation: A Cross‐Sectional Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Peritoneal dialysis (PD) is an established home‐based kidney replacement therapy (KRT), but its uptake remains low in Japan. We evaluated whether individualized education in a dedicated outpatient clinic was associated with the initiation of PD.
Yasuko Ito   +7 more
wiley   +1 more source

Slug Velocity Measurement and Flow Regime Recognition Using Acoustic Emission Technology [PDF]

open access: yes, 2013
Slug velocity measurement and flow regime recognition using acoustic emission technology are presented. Two non-intrusive and three intrusive methods were employed to detect the slug regime and measure its velocity using AE sensors. For the non-intrusive
Alssayh, Muammer Ali Ahmed
core   +3 more sources

An Overview of Computational Fluid Dynamics as a Tool to Support Ultrasonic Flow Measurements

open access: yesMetrology
Ultrasonic flow meters (UFMs) by transit time are ubiquitous in industrial applications, mainly for their versatility and practicality. They are widely used in gas and liquid installations, such as the oil and gas industry or feedwater systems in nuclear
Guilherme Siqueira de Aquino   +3 more
doaj   +1 more source

Free Flow and Discharge Characteristics of Trapezoidal-Shaped Weirs

open access: yesFluids, 2020
A number of studies have considered the effects of weir design variations on the free- and submerged-flow characteristics of trapezoidal broad-crested weirs. It appears that the hydraulics of short-crested weir flows have received little attention; thus,
Yebegaeshet T. Zerihun
doaj   +1 more source

Effect of DFPP on Ferroptosis in Peripheral Blood CD14+ Monocytes of Hyperlipidemic Patients Involving the ACSL4/LPCAT3/ALOX5 Pathway

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Hyperlipidemia is a major risk factor for atherosclerotic cardiovascular disease (ASCVD). Although statins are the cornerstone of lipid‐lowering therapy, their use may be limited in some patients by adverse effects. This study evaluated the possible impact of non‐drug treatment using double‐filtration plasmapheresis (DFPP) on CD14+
Yun Cheng   +3 more
wiley   +1 more source

Numerical analisys of flow conditioner efficiency

open access: yes, 2000
The use of flow conditioners becomes necessary in flow measurement applications where the geometry of conduits does not allow complete development of the velocity profile upstream the flowmeter.
Dell'Isola, M.   +4 more
core  

The Impact of Tenapanor on Body Composition and Blood Pressure in Peritoneal Dialysis Patients: A Pilot Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Instruction Tenapanor potentially affects fluid volume and blood pressure. This study explored its effects on these parameters in patients undergoing peritoneal dialysis (PD). Methods We conducted a single‐arm, prospective observational study that enrolled 10 patients on PD with hyperphosphatemia who were newly initiated on tenapanor.
Shun Yoshida   +11 more
wiley   +1 more source

Experimental Investigation of Aerodynamic Noise Generated by a Train-Car Gap

open access: yesJournal of Fluid Science and Technology, 2007
To investigate the mechanism of noise generation by a train-car gap, which is one of a major source of noise in Shinkansen trains, experiments were carried out in a wind tunnel using a 1/5-scale model train.
Fumio MIZUSHIMA   +4 more
doaj   +1 more source

Enteropathogenic E. coli shows delayed attachment and host response in human jejunum organoid‐derived monolayers compared to HeLa cells

open access: yesFEBS Letters, EarlyView.
Enteropathogenic E. coli (EPEC) infects the human intestinal epithelium, resulting in severe illness and diarrhoea. In this study, we compared the infection of cancer‐derived cell lines with human organoid‐derived models of the small intestine. We observed a delayed in attachment, inflammation and cell death on primary cells, indicating that host ...
Mastura Neyazi   +5 more
wiley   +1 more source