Results 11 to 20 of about 279,721 (202)
Background and Aim Goldman Applanation Tonometry (GAT), the gold standard of tonometry, is used without fluorescein in low‐resource settings. Nevertheless, corneal biomechanics differ among population groups. Purpose The aim of the study is to assess the
Tryness Munyapa +3 more
doaj +1 more source
Fundus Fluorescein Angiography
Fundus fluorescein angiography (FFA) is one of the age-old methods to examine the retinal and choroidal vasculature using dye namely sodium fluorescein.
Priyadarshi Gupta, Ekta Shaw
doaj +1 more source
Pneumocephalus is defined as intracranial air. Pneumaticcephaly is associated with several etiological factors, such as head injuries, surgical interventions, infections and neoplasms.
E. V. Shelesko +2 more
doaj +1 more source
Background: Previous studies showed that confocal laser endomicroscopy (CLE) images of brain tumors acquired by a first-generation (Gen1) CLE system using fluorescein sodium (FNa) contrast yielded a diagnostic accuracy similar to frozen surgical sections
Evgenii Belykh +13 more
doaj +1 more source
“Dye another day!” – dyes in ophthalmology
Background: Dyes are substances that are an integral part of ocular procedures and surgeries. In Clinical practice, dyes help in better visualization and aid in diagnoses of ocular surface disorders.
John S Vinitha +3 more
doaj +1 more source
Pulmonary Edema Following Intrathecal Fluorescein Injection; a Case Report
Intrathecal Fluorescein has been used widely for detection of cerebrospinal fluid (CSF) leakage. After administration of fluorescein many serious complications may happen.
Faranak Behnaz +3 more
doaj +1 more source
Labeling of Polysaccharides with Biotin and Fluorescent Dyes
Examples of labeling polysaccharides at hydroxyl groups are described in this paper, which are especially in demand for molecules with a blocked reducing end.
Alexander Tuzikov +8 more
doaj +1 more source
Cystatin C is an important cysteine protease inhibitor in the human body and is proposed as a new indicator of glomerular filtration rate for the detection of kidney damage.
Yuanjie Sun +8 more
doaj +1 more source
Despite the increasing popularity of flow diverters (FDs) as an endovascular option for intracranial aneurysms, the treatment of complex aneurysms still represents a challenge.
Francesco Acerbi +18 more
doaj +1 more source
The authors suggest improvement of oil deposit development systems in Tournaisian and Radaevskian-Bobrikovian sediments in zones of erosion incisions with permeable types of reservoirs using the example of the Ashalchinsky oilfield.
M.A. Saifutdinov +4 more
doaj +1 more source

