Results 101 to 110 of about 190,707 (309)

Focused Ultrasound-Mediated Hyperthermia in Vitro: An Experimental Arrangement for Treating Cells under Tissue-Mimicking Conditions.

open access: yes, 2019
An experimental arrangement that allows in vitro exposure of cells to focused ultrasound-mediated hyperthermia (43°C-55°C) in a tissue-mimicking phantom with biological, acoustic and thermal properties comparable to those of human soft tissue is ...
Brüningk, SC   +3 more
core   +1 more source

Understanding the Stochastic Nature of Process Parameter Development of Blown Powder Laser Beam Directed Energy Deposition Additive Manufacturing of Pure Molybdenum

open access: yesAdvanced Engineering Materials, EarlyView.
Identified through the use of statistical design of experiments and metallographic investigation, this study exposes the stochastic origins of intergranular cracks in blown powder laser beam directed energy deposition additive manufacturing of pure molybdenum. It further demonstrates a successful crack mitigation approach with direct correlation to the
Nathaniel J. Lies   +2 more
wiley   +1 more source

Feasibility of Transrib Focused Ultrasound Thermal Ablation for Liver Tumors Using a Spherically Curved 2d Array - a Numerical Study

open access: yes, 2008
The use of focused ultrasound thermal ablation to treat hepatocarcinorna and other liver tumors produces promising clinical results. However, one of the major drawbacks is the high absorption of ultrasonic energy by the rib, making partial rib removal ...
劉浩禮;張恕;陳文翔;施子卿;蕭仲凱;林文澧   +1 more
core  

Slip Localization Intensification Mediated by Grain Boundary Sliding in a Polycrystalline Nickel‐Based Superalloy

open access: yesAdvanced Engineering Materials, EarlyView.
The temperature dependence of fatigue behavior in nickel‐based superalloys is investigated through high‐resolution measurements of plastic localization. While increasing temperature reduces localization and enhances fatigue performance in René 88DT, Inconel 718 exhibits a sharp degradation at intermediate temperature due to intensified slip ...
M. Calvat   +5 more
wiley   +1 more source

Contrast-Agent-Enhanced Ultrasound Thermal Ablation

open access: yes, 2008
The small thermal lesions induced when using high-intensity focused ultrasound (HIFU) to ablate tumors results in long treatment duration. In this study. the effect of using ultrasound contrast agent (UCA.
CHEN, WEN-SHIANG;LIN, WIN-LI   +1 more
core  

Direct Metal Deposition of Graphene–Ti28Nb35.4Zr Matrix Composites With Enhanced Mechanical, Corrosion, and Biocompatibility Properties for Bone Implants

open access: yesAdvanced Engineering Materials, EarlyView.
Graphene nanoplatelet (0.1 wt.%) reinforcement significantly enhances the performance of β Ti‐28Nb‐35.4Zr alloy. Grain refinement, reduced water contact angle, and improved surface characteristics promote osteoblast adhesion and complete surface coverage after 7 days.
Khurram Munir   +5 more
wiley   +1 more source

Effects of high-intensity focused ultrasound on the intervertebral disc: A potential therapy for disc herniations

open access: yes, 2006
Purpose. To determine the potential application of high-intensity focused ultrasound for the minimally invasive treatment of herniated intervertebral discs by developing a probe that produces sufficiently high temperature locally to shrink collagen ...
Lars Lidgren   +15 more
core   +1 more source

Molecular Dynamics Studies of Shape Memory Polymers: From Bead–Spring Models to Atomistic Simulations

open access: yesAdvanced Engineering Materials, EarlyView.
Coarse‐grained (left) and atomistic (right) models of the shape memory polymer ESTANE ETE 75DT3 are shown schematically. The two representations bridge molecular detail and mesoscopic description. Both models capture shape memory behavior, linking segmental mobility and conformational relaxation of anisotropic chains to macroscopic recovery, and ...
Fathollah Varnik
wiley   +1 more source

Transcranial focused ultrasound for epilepsy

open access: yesBrain Stimulation, 2021
Ellen Bubrick   +5 more
doaj   +1 more source

Nondestructive Testing of Welded Composite Metal Foams

open access: yesAdvanced Engineering Materials, EarlyView.
X‐ray computed tomography (CT) is used to evaluate welded steel–steel composite metal foam (CMF) joints of two density classes. It reports variation in postweld spatial void distribution and correlates it to weld‐induced changes, mechanical performance, and failure within welded CMF panels.
Chinmaya Prerana Inguva   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy