IEEE transactions on power electronics
The three-phase four-leg inverter has garnered significant attention for its advantages in addressing unbalanced loads and other factors. However, compared to traditional three-phase three-leg inverters, the introduction of additional branches and the ...
Shuiqing Xu +7 more
semanticscholar +1 more source
The three-phase four-leg inverter has garnered significant attention for its advantages in addressing unbalanced loads and other factors. However, compared to traditional three-phase three-leg inverters, the introduction of additional branches and the ...
Shuiqing Xu +7 more
semanticscholar +1 more source
IEEE Transactions on Industrial Electronics, 2017
Mohammad Pichan, Hasan Rastegar
exaly +2 more sources
Mohammad Pichan, Hasan Rastegar
exaly +2 more sources
The Power Electronics, Drive Systems & Technologies Conference, 2021
In this study, a model predictive control (MPC) method is used to control a four-leg voltage source inverter in a stand-alone microgrid. The proposed method aims to regulate the voltage of the inverter so that the cost function of the MPC becomes minimum.
M. Koushki +3 more
semanticscholar +1 more source
In this study, a model predictive control (MPC) method is used to control a four-leg voltage source inverter in a stand-alone microgrid. The proposed method aims to regulate the voltage of the inverter so that the cost function of the MPC becomes minimum.
M. Koushki +3 more
semanticscholar +1 more source
Symmetry
Virtual synchronous generator (VSG) control has positive effects on the stability of microgrids. In practical power systems, both single-phase loads and three-phase unbalanced loads are present.
Zhenshan Huang +5 more
semanticscholar +1 more source
Virtual synchronous generator (VSG) control has positive effects on the stability of microgrids. In practical power systems, both single-phase loads and three-phase unbalanced loads are present.
Zhenshan Huang +5 more
semanticscholar +1 more source
International Conference on Electrical Machines and Systems, 2021
This paper proposes unbalanced load compensation (LUC) method with artificial neural network (ANN) for grid-connected four-leg inverter. The proposed method consists of reference calculation and controllers for compensating the unbalanced current for ...
C. An +5 more
semanticscholar +1 more source
This paper proposes unbalanced load compensation (LUC) method with artificial neural network (ANN) for grid-connected four-leg inverter. The proposed method consists of reference calculation and controllers for compensating the unbalanced current for ...
C. An +5 more
semanticscholar +1 more source
Model Predictive Control of a Two-Motor Drive Using a Four-Leg Inverter
International Electric Machines and Drives Conference, 2021In this paper, a cost-effective four-leg inverter is proposed to independently control two three-phase permanent magnet synchronous motors (PMSM). In this topology, one of the phases of the three-phase PMSM is connected to the midpoint of the dc-link ...
S. Saeidabadi, L. Parsa
semanticscholar +1 more source
A Study of a 3-Phase Four-Leg Inverter Dynamic Operation
2018 International Conference on Engineering Technology and their Applications (IICETA), 2018this paper deals with an analysis and study of 3P4L-VSI using the 3D-SVPWM technique. The analysis adopts the average large signal model. The work intended to show the ability of this inverter to overcome the challenge of feeding unbalanced, nonlinear and continuously changed load with balanced 3-phase voltages.
Isam M. Abdulbaqi +2 more
openaire +1 more source
2024 6th International Conference on Energy Systems and Electrical Power (ICESEP)
Three-level three-phase four-leg (3L3P4L) inverter is widely used in uninterruptible power supply because it can provide a path for zero-sequence current components and realize operation under asymmetric load conditions.
Mingcong Xia +7 more
semanticscholar +1 more source
Three-level three-phase four-leg (3L3P4L) inverter is widely used in uninterruptible power supply because it can provide a path for zero-sequence current components and realize operation under asymmetric load conditions.
Mingcong Xia +7 more
semanticscholar +1 more source
A simple control technique for three-phase four-leg inverters
International Symposium on Power Electronics, Electrical Drives, Automation and Motion, 2006. SPEEDAM 2006., 2006The paper takes into consideration three-phase four-leg inverters used to supply unbalanced loads without using a transformer. In literature different three-dimensional modulation techniques, requiring complex mathematical algorithms are proposed for this kind of inverter.
A. Bellini, S. Bifaretti
openaire +1 more source
Dead-Time Compensation to Reduce the Common Mode Voltage in a Three-Phase Four-Leg Inverter
European Conference on Cognitive ErgonomicsThis paper presents a novel digital control to mitigate the common mode voltage (CMV) produced by the switching events of a four-leg grid-following voltage source inverter (VSI).
R. Tubbs, A. Julian, G. Oriti