Results 1 to 10 of about 8,674 (155)
Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems [PDF]
Eliminating the leakage current is one of the most important issues for transformerless three phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common mode loop model established, the generation mechanism of the leakage current is clearly identified. Different
Guo, Xiaoqiang +5 more
core +6 more sources
A new control scheme for three-phase four-leg inverter
In the unbalanced or non-linear load conditions, the ordinary three-phase three-leg inverter can not produce three-phase symmetrical voltage, based on the Simulink simulation platform, this paper presents a new closed-loop control design scheme for three-
Sun Lingfang, Li Zhiyuan, Ji Huichao
doaj +2 more sources
Three-phase four-leg flying-capacitor multi-level inverter-based active power filter for unbalanced current operation. [PDF]
This study describes a new application of flying capacitor multi-level inverters whereby a three-phase, four-leg three-level inverter is used for harmonic current cancellation and unbalanced current compensation in a four-wire system.
Benjamin Chong +7 more
core +3 more sources
Digital Predictive Current Control of a Three-Phase Four-Leg Inverter
While the classical control techniques for threephase two-level four-leg inverters are based on pulse width modulation or three-dimensional space vector modulation, this paper presents a simple digital current control strategy without the modulation stage.
Marco Rivera +5 more
openaire +3 more sources
A State-Space Approach to the Modelling and Control of the Neutral Leg of a Four Legs, Three-Phase Inverter [PDF]
In this paper, a novel approach to determine the model of an ICNL (Independently Controlled Neutral Leg) is proposed. Based on this model, a cascaded control method is developed to provide a steady neutral point connection for a three-phase four-wire inverter and to balance the two DC capacitors voltages of a split DC-bus.
Massimiliano Passalacqua +5 more
openaire +4 more sources
Minimum Loss Discontinuous Pulse-Width Modulation Per Phase Method for Three-Phase Four-Leg Inverter
The three-phase four-leg inverter (TPFLI) provides unbalanced voltage to a load or injects unbalanced current to a grid to compensate unbalanced current. However, it has a high switching loss because of the fourth leg. This paper presents a discontinuous
Soo Yeon Kim +2 more
doaj +3 more sources
An individual sequencing control strategy for three-phase four-leg inverter under unbalanced loads
Under the influence of the unbalanced load, the negative and zero sequence components in the output voltage of the three-phase four-leg voltage source inverter(TPFL-VSI) will cause asymmetry voltage.
Hanzhou Jiang, Huan Pan, Bin Shang
doaj +3 more sources
Model Predictive Control for Three-Phase Four-Leg Grid-Tied Inverters
In order to improve the quality of the power injected into a grid, this paper presents a model predictive control strategy for three-phase four-leg grid-tied inverters. For the convenience of optimization, the discrete-time model of the inverter in which
Qihong Chen +3 more
doaj +2 more sources
A three-phase four-leg inverter-based shunt active power filter (APF) is proposed to compensate three-phase unbalanced currents under unbalanced load conditions in grid-connected operation in this study.
Kuang-Hsiung Tan +2 more
doaj +3 more sources
The three-phase four-leg inverter can produce balanced voltages even with unbalanced loads, yet its controller design is quite complicated. Based on the analysis on time domain equations, a decoupled sequence control strategy for the three-phase four-leg
Botong Li, Jianfei Jia, Shimin Xue
doaj +3 more sources