Results 1 to 10 of about 208 (185)
A new control scheme for three-phase four-leg inverter
In the unbalanced or non-linear load conditions, the ordinary three-phase three-leg inverter can not produce three-phase symmetrical voltage, based on the Simulink simulation platform, this paper presents a new closed-loop control design scheme for three-
Sun Lingfang, Li Zhiyuan, Ji Huichao
doaj +2 more sources
Model Predictive Control for Three-Phase Four-Leg Grid-Tied Inverters
In order to improve the quality of the power injected into a grid, this paper presents a model predictive control strategy for three-phase four-leg grid-tied inverters. For the convenience of optimization, the discrete-time model of the inverter in which
Qihong Chen +3 more
doaj +2 more sources
A three-phase four-leg inverter-based shunt active power filter (APF) is proposed to compensate three-phase unbalanced currents under unbalanced load conditions in grid-connected operation in this study.
Kuang-Hsiung Tan +2 more
doaj +3 more sources
The three-phase four-leg inverter can produce balanced voltages even with unbalanced loads, yet its controller design is quite complicated. Based on the analysis on time domain equations, a decoupled sequence control strategy for the three-phase four-leg
Botong Li, Jianfei Jia, Shimin Xue
doaj +3 more sources
Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems [PDF]
Eliminating the leakage current is one of the most important issues for transformerless three-phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common-mode loop model established, the generation mechanism of the leakage current is clearly identified. Different
Josep M Guerrero +2 more
exaly +2 more sources
Control strategy of parallel three-phase four-leg inverter under unbalanced conditions
A compound control strategy is proposed in order to solve the low control accuracy and poor anti-disturbance of deadbeat control. In this method, the repetitive control is embedded into the deadbeat control to improve the robustness of the control system
Zhu Zhenyuan +3 more
doaj +2 more sources
A high computational burden is required in conventional model predictive control, as all of the voltage vectors of a power inverter are used to predict the future behavior of the system.
Abdul Mannan Dadu +4 more
doaj +3 more sources
Sliding mode controller for four leg shunt active power filter to eliminating zero sequence current, compensating harmonics and reactive power with fixed switching frequency [PDF]
In this paper, the four leg inverter controlled by the three dimensional space vector modulation (3D SVM) is used as the shunt active power filter (SAPF) for compensating the three phase four wire electrical network, by using the four leg ...
Chebabhi Ali +3 more
doaj +1 more source
With the continuous penetration and development of renewable energy power generation, distributed grids and microgrids are becoming increasingly important in power systems.
Guoli Feng +4 more
doaj +1 more source
The grid-connected non-isolated photovoltaic inverter system suffers from the leakage current, which increases the loss of the system, and the grid-connected current harmonics impact the normal operation of the equipment.
Dong Yang, Kaiwen Yang, Fengyang Gao
doaj +1 more source