Results 71 to 80 of about 586,608 (155)

Omnipod 5 Delivers Superior Economic Value Compared to Multiple Daily Injections: A Cost‐Effectiveness Analysis in Adults With T1D From a Payer Perspective in Sweden

open access: yesDiabetes, Obesity and Metabolism, Volume 28, Issue 11, Page 10142-10152, November 2026.
ABSTRACT Aim Analyse the cost‐effectiveness of the Omnipod 5 automated insulin delivery system versus multiple daily injections (MDI) with continuous glucose monitoring for type 1 diabetes among adults in Sweden. Methods Cost‐effectiveness was analysed with the IQVIA Core Diabetes Model (version 10.0) taking the perspective of the payer in Sweden ...
Johan Jendle   +5 more
wiley   +1 more source

Glucose values from the same continuous glucose monitoring sensor significantly differ among readers with different generations of algorithm

open access: yesScientific Reports
Continuous glucose monitoring (CGM) values obtained from CGM systems using the same sensor but with different internal algorithms (the first- and third-generation FreeStyle Libre (1st-gen-libre and 3rd-gen-libre, respectively)) were compared.
Naru Babaya   +9 more
doaj   +1 more source

Person‐Reported and Continuous Glucose Monitoring (CGM) Recorded Hypoglycaemia in People With Insulin‐Treated Type 2 Diabetes and Mild to Moderate Chronic Kidney Disease; Post Hoc Analysis From the Hypo‐METRICS Study

open access: yesDiabetes, Obesity and Metabolism, Volume 28, Issue 11, Page 10664-10669, November 2026.
ABSTRACT Background and Aims People with diabetes and chronic kidney disease (CKD) may be at increased risk of iatrogenic hypoglycaemia. We compared rates of sensor‐detected (SDH) and person‐reported hypoglycaemia (PRH) in people with insulin‐treated Type 2 diabetes (T2D) with and without CKD in the Hypo‐METRICS study.
Julie M. B. Brøsen   +39 more
wiley   +1 more source

FreeStyle Libre and Dexcom G4 Platinum sensors: Accuracy comparisons during two weeks of home use and use during experimentally induced glucose excursions

open access: yes, 2018
This study compared the accuracy of the FreeStyle Libre (Abbott, Alameda, CA) and Dexcom G4 Platinum (DG4P, Dexcom, San Diego, CA) CGM ...
Marescotti, M C   +15 more
core   +1 more source

Rationale and design of a randomised phase II multicentre crossover trial investigating a sodium-glucose co-transporter 2 inhibitor, dapagliflozin, combined with a novel continuous ketone monitor in adults with type 1 diabetes to reduce the risk of diabetic ketoacidosis: the PARTNER study

open access: yesBMJ Open
Introduction Sodium-glucose co-transporter inhibitors have potential glycaemic and non-glycaemic benefits in people with type 1 diabetes (T1D). However, the increased risk of diabetic ketoacidosis (DKA) limits their widespread use.
Yee Wen Kong   +17 more
doaj   +1 more source

Internet of Things Based on Electronic and Mobile Health Systems for Blood Glucose Continuous Monitoring and Management

open access: yesIEEE Access, 2019
Over 425 million people suffer from diabetes worldwide and this number is expected to increase over the years. Rigorous and extensive research has led to the development of increasingly advanced technologies, such as continuous glucose monitoring and ...
Jose Jorge Rodrigues Barata   +4 more
doaj   +1 more source

The Impact of Diabetes Education on Continuous Glucose Monitoring in SUS-Dependent Patients in a Northeastern Brazilian City

open access: yesLife
Background: Diabetes Mellitus (DM) is an important chronic disease that occurs worldwide. Aims: This study aims to investigate how the use of the FreeStyle® Libre system in Unified Health System (SUS) patients impacts diabetes parameters in patients who ...
Lysandro Pinto Borges   +19 more
doaj   +1 more source

Effect of 6 months’ flash glucose monitoring in adolescents and young adults with type 1 diabetes and suboptimal glycaemic control: managing diabetes in a ‘flash’ randomised controlled trial protocol

open access: yesBMC Endocrine Disorders, 2019
Background Teenagers and young adults with type 1 diabetes (T1D) experience significant burden managing this serious chronic condition and glycaemic control is at its unhealthiest during this life stage. Flash glucose monitoring (FGM) is a new technology
Sara E. Boucher   +8 more
doaj   +1 more source

The impact of continuing glucose (FreeStyle Libre) monitoring on the diabetes regulation and life quality of the patients with diabetes

open access: yes, 2021
Šećerna bolest je jedna od najčešćih kroničnih nezaraznih bolesti, a možemo je svrstati u globalne epidemije jer broj oboljelih svakodnevno raste. Obzirom da je šećerna bolest bolest kroničnog tipa, sa sobom nosi rizik razvoja kroničnih komplikacija na ...
Jozinović, Dijana
core   +1 more source

Beyond the CE Mark: A Call to Action for Minimum CGM Accuracy Standards in Central and Eastern European Nations

open access: yes
Diabetes, Obesity and Metabolism, Volume 28, Issue 11, Page 9747-9752, November 2026.
Tomasz Klupa   +14 more
wiley   +1 more source

Home - About - Disclaimer - Privacy