Fructosamine measurements in serum and plasma
Clinica Chimica Acta, 1987Serum fructosamine concentration measured by the reduction of nitro-blue tetrazolium in alkaline solution [l], has been shown to be simple, inexpensive and useful in the assessment of glucose homeostasis both in type I (insulin dependent) [3-51 and type II (non-insulin dependent) diabetes mellitus [6]. This assay has now been adapted for many automated
D, MacDonald +3 more
openaire +2 more sources
Serum Fructosamine and Retinopathy of Prematurity
The Indian Journal of Pediatrics, 2011To determine whether serum fructosamine which is a good marker for detecting hyperglycemia during the previous 2 to 3 wk in infants could predict the development of retinopathy of prematurity in very low birth weight infants.One hundred sixty seven premature infants who had a birth weight of < 1500 g and a gestational age of less than 32 wk were ...
Senol, Bozdag +7 more
openaire +2 more sources
Variability of the fructosamine assay in pregnancy
Diabetologia, 1987Dans la matinee, la variabilite sur 3 heures du dosage de la fructosamine n'excede pas la variance analytique. Possibilite de corriger les valeurs de fructosamine par rapport aux concentrations plasmatiques de proteines ou d ...
openaire +2 more sources
Fructosamine III: Prologue or Epitaph?
Diabetes Technology & Therapeutics, 1999457 O ’BRIEN AND BROOKES describe one of the first evaluations of a third-generation fructosamine assay, one specific for the ketoamine bond of glycated serum proteins.1 This work was presumably done to establish the product labeling of the Genzyme GlyPro assay (Cambridge, MA).2 Healthy fasting individuals without a history of diabetes provided blood ...
openaire +2 more sources
Fructosamine: How Useful Is It?
Laboratory Medicine, 1990The goal of laboratory medicine is to provide laboratory tests that are useful to physicians in the diagnosis, treatment, and monitoring of their patients. The best laboratory medicine also encompasses participating in the care of patients by ensuring that these laboratory tests are wisely used.
openaire +1 more source
Fructosamine in a diabetic clinic.
The New Zealand medical journal, 1988Serum fructosamine concentrations were measured in 660 adults attending the diabetic clinic at Auckland Hospital over a 12 month period. Only 44 (6.6%) patients had results within the physiological range whereas 237 (35.9%) patients had values greater than 3.7 mmol/l consistent with poor blood glucose control.
J, Baker, R, Cutfield, W, Taylor
openaire +1 more source
The why and wherefore of fructosamine.
Henry Ford Hospital medical journal, 1992GH and FA are useful monitors in the care of diabetic patients. For most situations, GH is the preferred test and should be routinely monitored. FA should be reserved for exceptional situations in which blood glucose control over one to two weeks must be assessed or in patients with a hemoglobinopathy.
D B, Mendlovic +2 more
openaire +1 more source
Fructosamine or Glycated Hemoglobin?
Journal of the American Geriatrics Society, 1989openaire +2 more sources