Adaptive Ultrasonic Full Matrix Capture Process for the Global Imaging of Complex Components with Curved Surfaces [PDF]
This work proposes a new global FD-RTM method to solve the problem of ultrasonic inspection of parts with complex geometric shapes. With this method, the frequency domain reverse time migration (FD-RTM) algorithm is used to adapt to the complex ...
Wensong Miao +3 more
doaj +6 more sources
Locally Optimal Subsampling Strategies for Full Matrix Capture Measurements in Pipe Inspection [PDF]
In ultrasonic non-destructive testing, array and matrix transducers are being employed for applications that require in-field steerability or which benefit from a higher number of insonification angles.
Fabian Krieg +5 more
doaj +6 more sources
A Modified Wavenumber Algorithm of Multi-Layered Structures with Oblique Incidence Based on Full-Matrix Capture [PDF]
Full-matrix capture (FMC)-based ultrasonic imaging provides good sensitivity to small defects in non-destructive testing and has gradually become a mainstream research topic.
Bei Yu +5 more
doaj +6 more sources
A High-Speed Ultrasound Full-Matrix Capture Acquisition System for Robotic Weld Inspection [PDF]
Phased-Array Ultrasonic Technique is traditionally used for the non-destructive inspection of welds and supported by industrial-grade inspection equipment. FullMatrix Capture (FMC) with Total Focusing Method (TFM) provide new capabilities and multimodal
Marcin Lewandowski +5 more
doaj +3 more sources
Automated Application of Full Matrix Capture to Assess the Structural Integrity of Mooring Chains
In-service mooring chains are subjected to harsh environmental conditions on a daily basis, which increases the necessity of integrity assessment of chain links.
Mahesh Dissanayake +6 more
doaj +5 more sources
Laser induced ultrasonic phased array using Full Matrix Capture data acquisition and Total Focusing Method [PDF]
Laser based ultrasound is a technique where a short pulsed laser is used to generate ultrasound and optical interferometry is used in order to detect the signal.
Clark, Matt +2 more
core +10 more sources
Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique
Abstract A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased
Tae-Hun Lee, Jeong-Seok Lee
exaly +4 more sources
Diffuse field full matrix capture for near surface ultrasonic imaging [PDF]
This article reports a technique for near-surface ultrasonic array imaging. Information equivalent to an undelayed full matrix of inter-element responses is produced through cross-correlation of a later time diffuse full matrix. This reconstructed full matrix lacks the nonlinear effects of early time saturation present in a directly acquired response ...
Potter, J. N. +2 more
openaire +5 more sources
Full matrix capture and the total focusing imaging algorithm using laser induced ultrasonic phased arrays [PDF]
Laser ultrasonics is a technique where lasers are used for the generation and detection of ultrasound instead of conventional piezoelectric transducers.
Clark, Matt +2 more
core +5 more sources
Acoustic Signal Imaging Method Based on Synthetic Aperture Focusing and Full Matrix Capture
In order to observe and understand the effect of acoustic signal detection more intuitively, imaging analysis is needed to obtain clearer detection results, and the detection situation is analyzed manually. The commonly used imaging method is B-scan imaging, which is also widely used in medical imaging.
Tian Gao +5 more
openaire +3 more sources