Results 81 to 90 of about 220,311 (341)

Shielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas ...
Michael Oumano   +12 more
wiley   +1 more source

Imaging and Spectral Fitting of Bright Gamma-Ray Sources with the COSI Balloon Payload

open access: yesThe Astrophysical Journal
The Compton Spectrometer and Imager balloon payload (COSI-Balloon) is a wide field-of-view Compton gamma-ray telescope that operates in the 0.2–5 MeV bandpass.
Jarred M. Roberts   +19 more
doaj   +1 more source

Analysis of open source license selection for the GitHub programming community [PDF]

open access: yesarXiv, 2020
Developers usually select different open source licenses to restrain the conditions of using open source software, in order to protect intellectual property rights effectively and maintain the long-term development of the software. However, the open source community has a wide variety of licenses available, developers generally find it difficult to ...
arxiv  

Soft gamma-ray sources detected byINTEGRAL [PDF]

open access: yesAstronomy & Astrophysics, 2009
We aim to exploit the available INTEGRAL/SPI data to provide time-averaged spectra of the brightest soft gamma-ray sources. Employing a maximum-likelihood fit technique for our SPI data analysis, we take as input to our source model the source catalog derived by Bouchet et al. (2008) from a SPI all-sky study.
Petry, D.   +3 more
openaire   +6 more sources

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

A Study on the Line of Sight to Galaxies Detected at Gamma-Ray Energies

open access: yesThe Astrophysical Journal Letters
The large-scale universal structure comprises strands of dark matter and galaxies with large underdense volumes known as voids. We measure the fraction of the line of sight that intersects voids for active galactic nuclei (AGN) detected by Fermi Large ...
Amy Furniss   +4 more
doaj   +1 more source

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

The ergodic decomposition of asymptotically mean stationary random sources [PDF]

open access: yesarXiv, 2008
It is demonstrated how to represent asymptotically mean stationary (AMS) random sources with values in standard spaces as mixtures of ergodic AMS sources. This an extension of the well known decomposition of stationary sources which has facilitated the generalization of prominent source coding theorems to arbitrary, not necessarily ergodic, stationary ...
arxiv  

Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

Extragalactic Gamma-Ray Sources [PDF]

open access: yes, 2004
This chapter provides a review of γ-ray sources lying at high Galactic latitudes. Their statistical properties and variability status, as well as studies involving cross correlations with lower frequency catalogs and multiwavelength observations, are summarized. The case for active galactic nuclei is analyzed with special emphasis, since they represent
openaire   +2 more sources

Home - About - Disclaimer - Privacy