Results 171 to 180 of about 4,686 (224)
Some of the next articles are maybe not open access.

Real-time gas insulation state evaluation model of the gas insulated switchgear

2017 13th International Conference on Natural Computation, Fuzzy Systems and Knowledge Discovery (ICNC-FSKD), 2017
Gas insulated switchgear (GIS) has been applied greatly in the ultra-high voltage (UHV) power grids because of its advantages of high reliability, compact structure, small footprint, low electromagnetic pollution and so on. Therefore, the real-time monitoring of its operation status is important for ensuring the reliable and safe operation of the power
Jianxia Chen   +6 more
openaire   +1 more source

Transient heating of gas insulated switchgears

IEEE PES T&D 2010, 2010
This paper investigates the thermal effects of short fault currents in switchgears. During short circuits, the current and temperature distribution over the cross section and even along the perimeter of the busbars and the enclosures can become non-uniform, exposing the separate contact elements of the contact systems to different temperatures.
L. Koller, B. Novak
openaire   +1 more source

Sustainable performance of Gas-Insulated Switchgear

2012 International Conference on High Voltage Engineering and Application, 2012
Modern Gas Insulated Switchgear (GIS) technology has been undergoing continual development since its introduction in the 1960's when the use of SF6 as arc extinguishing and isolating medium was first introduced, and whilst many may consider this technology as mature, there have been continuous development driven changes in GIS design, manufacture, test
Peter Glaubitz   +3 more
openaire   +1 more source

Testing Methods for Gas-Insulated Switchgear

IEEE Transactions on Electrical Insulation, 1986
This paper presents the outline and basic concepts of insulation tests which have been contributing to GIS's steady progress in Japan. Some examples of insulation tests during developing, production, and installation stages are described. Finally, the current trends of GIS's insulation tests are described.
T. Yamauchi   +3 more
openaire   +1 more source

Application of BDS in Deformation Monitoring for Gas Insulated Switchgear

2021 IEEE 5th Advanced Information Technology, Electronic and Automation Control Conference (IAEAC), 2021
Aiming at the problem that it is difficult to obtain the complete and timely device status information of gas-insulated switchgear for traditional methods in deformation monitoring, leading to unable to accurately control the device, which will influence the substation’s safe operation for sure, the paper proposed to use BDS independently developed by ...
LI Xiaoguang   +3 more
openaire   +1 more source

Gas Insulated Switchgear GIS - State of the Art

2007 IEEE Power Engineering Society General Meeting, 2007
Gas insulated switchgear (GIS) is a world-wide used technology to solve the needs and requirements coming from modern power transmission and distribution systems. In this paper the development of the GIL technology is presented, design features are explained and a focus is given to the manufacturing process to show the high quality of the production of
Phil Bolin, Hermann Koch
openaire   +1 more source

Development of 800 kV gas-insulated switchgear

IEEE Transactions on Power Delivery, 1992
An 800 kV gas-insulated switchgear, with a capacity level recognized as the largest in the world, was developed as the first development of UHV gas-insulated switchgear, and good results were obtained in the type tests for this switchgear. With the gas circuit breaker and the disconnector used in this gas-insulated switchgear, tests on a scale ...
H. Toda   +5 more
openaire   +1 more source

Coupling Devices for the Detection of Partial Discharges in Gas-insulated Switchgear

IEEE Power Engineering Review, 1981
Partial discharge in gas-insulated 8witchgear is indicative of serious malfunction and, otten, imminent failure. Partial discharge magnitudes range from zero to about a microcoulomb per pulse. Sources of partial discharge can be detected acoustically, electromagnetically or through gas analysis.
S.A. Boggs, G.L. Ford, R.C. Madge
openaire   +1 more source

Determination of Sensor Position on 150 kV Gas Insulation Switchgear

2019 International Conference on Electrical Engineering and Informatics (ICEEI), 2019
Gas insulated switchgear is one of the important equipment in electric power system. Gas insulated switchgear can run into a malfunction that begins with the presence of partial discharge. Various methods have been developed to detect the presence of partial discharge.
Umar Khayam   +2 more
openaire   +1 more source

Contact‐failure phenomena and their development in gas‐insulated switchgear

Electrical Engineering in Japan, 1993
AbstractTo explain contact failure phenomena and their development in the gas‐insulated switchgear (GIS). tests were conducted by simulating abnormal current‐carrying conditions using an actual 300‐kV, 2000‐A GIS.This paper describes the process observed. ranging from contact failures to ground faults, deteriorative phenomena and some detection methods
Yoku Mukaiyama   +5 more
openaire   +1 more source

Home - About - Disclaimer - Privacy