Results 161 to 170 of about 2,277,341 (203)
Some of the next articles are maybe not open access.
IEEE Transactions on Power Delivery, 2017
Several methods have been proposed and investigated so far on mitigation of very fast transient overvoltages (VFTO) in gas-insulated switchgear (GIS). The state-of-the-art methods are primarily based on dissipation of the energy associated with electromagnetic waves that the VFTO originate from and are composed of.
Maciej Kuniewski +2 more
exaly +2 more sources
Several methods have been proposed and investigated so far on mitigation of very fast transient overvoltages (VFTO) in gas-insulated switchgear (GIS). The state-of-the-art methods are primarily based on dissipation of the energy associated with electromagnetic waves that the VFTO originate from and are composed of.
Maciej Kuniewski +2 more
exaly +2 more sources
IEEE Transactions on Dielectrics and Electrical Insulation, 2007
Gas insulated switchgear (GIS) has been increasingly being used in recent years and high reliability and rational insulation design are required. This research provided V-N characteristics (the dielectric breakdown voltage versus number of repetitions characteristics) regarding the internal insulation and creeping insulation of the epoxy spacer, which ...
Shigemitsu Okabe
exaly +2 more sources
Gas insulated switchgear (GIS) has been increasingly being used in recent years and high reliability and rational insulation design are required. This research provided V-N characteristics (the dielectric breakdown voltage versus number of repetitions characteristics) regarding the internal insulation and creeping insulation of the epoxy spacer, which ...
Shigemitsu Okabe
exaly +2 more sources
Analisis dan Efisiensi Kebutuhan Kapasitas Baterai 110 Volt DC Gas Insulated Switchgear (GIS) 150 KV Wonokromo Surabaya [PDF]
Penyaluran energi listrik pada Gas Insulated Switchgear (GIS) memiliki dua sumber tenaga, yaitu sumber (AC) bolak balik dan (DC) searah. Salah satu sumber DC yang memiliki peran yang sangat penting adalah baterai 110 VDC. Baterai merupakan suatu sel listrik yang terdapat dua proses elektrokimia, yaitu proses discharging dan proses charging.
Andrian Nuril Ihsan +3 more
openaire +2 more sources
2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe), 2023
Marcos Tello +2 more
exaly +2 more sources
Marcos Tello +2 more
exaly +2 more sources
2024 14th International Conference on System Engineering and Technology (ICSET)
Mohd Hezri Fazalul Rahiman
exaly +2 more sources
Mohd Hezri Fazalul Rahiman
exaly +2 more sources
Advanced Metal Oxide Surge Arrester for Gas Insulated Switchgear (GIS)
IEEE Power Engineering Review, 1984SF6 gas has outstanding dielectric strength and heat transfer property. This suggests that zinc oxide (ZnO) elements whose value of E in E-J characteristic is higher than the value of the elements used in a porcelain type arrester is suitable to metal enclosed metal oxide surge arresters (MOA) for gas insulated switchgears (GIS). Several kinds of newly
M. Imataki +4 more
openaire +1 more source
Highly integrated and compact gas-insulated switchgear (GIS) for 4000 A and 63 kA
2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495), 2004An up-rated gas-insulated switchgear (GIS)- product in the voltage range up to 170 kV with 4000 A continuous current and 63 kA short circuit current is now available, which in these ratings is the most compact design in this market segment. This recently developed GIS is based on the existing GIS type ELK-0 (which is established in the market since ...
T. Betz +4 more
openaire +1 more source
A surface resistivity probe for assessing solid insulators in GIS (gas insulated switchgear)
IEEE International Symposium on Electrical Insulation, 2002The changes in surface characteristics after a spacer has been exposed to a large amount of SF/sub 6/ decomposition products for a short period of time, which is similar to conditions during fault repair, are described. The design and construction of a prototype surface electrical resistivity probe which can be used to assess the reusability of ...
J.M. Braun, F.Y. Chu, R. Seethapathy
openaire +1 more source
Coating and barrier within medium voltage GIS (gas insulated switchgear)
IET Conference Publications, 2009The main purpose of this paper is to investigate ca ses with atmospheric air and hybrid insulation, where solid insulation is used in addition to air. For solid insulation, convenient polymeric materials are used. With hybri d insulation it is typically two options: Coating or barriers.
T. Oyvang, S.T. Hagen
openaire +1 more source