Two planar antennas for detection of partial discharge in gas-insulated switchgear (GIS)
2015 IEEE International Conference on Communication, Networks and Satellite (COMNESTAT), 2015The detection of partial discharge in GIS plays a pivotal role in preventing and mitigating severe operational failure and damage in insulation elements. Partial discharge progressively degrades the insulating medium and, as a result electrical breakdown can occur in GIS.
Diego Lozano-Claros +2 more
openaire +1 more source
Emerging Technologies in High Voltage Gas Insulated Switchgear-Clean Air GIS and NCIT
2019 International Conference on High Voltage Engineering and Technology (ICHVET), 2019Presently, the Gas insulated switchgears (GIS) are used extensively in the power transmission and distribution systems worldwide. The compactness and durability of Gas insulated switchgear is the key reason for their popularity. The compactness is mainly because of presence of SF6 gas, having the best characteristics as an insulating and quenching ...
Dharababu Thummapal +2 more
openaire +1 more source
International Journal of Emerging Electric Power Systems, 2021
Abstract Insulation based on epoxy resin (ER) is widely used for high voltage and high fault current rated electrical substation equipment. This paper details the formulation of epoxy based Nano-composites and influence of the Nano filler material on the electrical and thermal properties like breakdown voltage ...
Rathod Hari, Mandava Mohana Rao
openaire +1 more source
Abstract Insulation based on epoxy resin (ER) is widely used for high voltage and high fault current rated electrical substation equipment. This paper details the formulation of epoxy based Nano-composites and influence of the Nano filler material on the electrical and thermal properties like breakdown voltage ...
Rathod Hari, Mandava Mohana Rao
openaire +1 more source
Industrial Robot: the international journal of robotics research and application, 2022
Purpose The purpose of this paper is to achieve optimal climbing control of the gas-insulated switchgear (GIS) robot, as the authors know that the GIS inspection robot is a kind of artificial intelligent mobile equipment which auxiliary or even substitute human labor drive on the inner wall of the gas-insulated metal enclosed switchgear.
Zhimin Pan +5 more
openaire +1 more source
Purpose The purpose of this paper is to achieve optimal climbing control of the gas-insulated switchgear (GIS) robot, as the authors know that the GIS inspection robot is a kind of artificial intelligent mobile equipment which auxiliary or even substitute human labor drive on the inner wall of the gas-insulated metal enclosed switchgear.
Zhimin Pan +5 more
openaire +1 more source
Ultra-High Frequency (UHF) Based Partial Discharge Measurement in Gas Insulated Switchgear (GIS)
2019 International Conference on High Voltage Engineering and Technology (ICHVET), 2019Gas Insulated Substations (GIS) offer significant advantages over conventional Air Insulated Substations (AIS) on account of reduced space and operational efficiency. Partial discharge (PD) measurement is one of the important test in GIS to ensure its reliability during service and also to reveal defects at incipient levels. One of the methods employed
M. Mohana Rao, Mrituniav Kumar
openaire +1 more source
2015 IEEE 15th International Conference on Environment and Electrical Engineering (EEEIC), 2015
This paper presents the EMC (Electromagnetic Compatibility) philosophy applied to design the grounding systems of GIS Insulated Substation - GIS indoor substation. The grounding systems are characterized by the following subsystems: Main Grounding grid (60 Hz Grounding System), Equipotential Grounding grid (HF Grounding system) and Lightning Grounding ...
Marcos Tello +4 more
openaire +1 more source
This paper presents the EMC (Electromagnetic Compatibility) philosophy applied to design the grounding systems of GIS Insulated Substation - GIS indoor substation. The grounding systems are characterized by the following subsystems: Main Grounding grid (60 Hz Grounding System), Equipotential Grounding grid (HF Grounding system) and Lightning Grounding ...
Marcos Tello +4 more
openaire +1 more source
2006 China International Conference on Electricity Distribution (CICED 2006), 2006
The requirements towards an up to date gas insulated switchgear design and their realization including its security, reliability and safety is discussed. The capability of the design to provide higher safety, higher security and higher reliability is based on the manufacturer's individual design.
R. Buchenau, W. Hartmut
openaire +1 more source
The requirements towards an up to date gas insulated switchgear design and their realization including its security, reliability and safety is discussed. The capability of the design to provide higher safety, higher security and higher reliability is based on the manufacturer's individual design.
R. Buchenau, W. Hartmut
openaire +1 more source
Beiträge aus der Plasmaphysik, 1985
AbstractGIS for operation voltages ≧ 245 kV can be tested with oscillating impulse voltages on site advantageously, because this H. V. test can be performed with easily mountable impulse generators. The IEC recommendation for on‐site testing of GIS which is now under discussion doesn't fix the time parameters of the oscillating impulse voltages, but ...
W. Hauschild +3 more
openaire +1 more source
AbstractGIS for operation voltages ≧ 245 kV can be tested with oscillating impulse voltages on site advantageously, because this H. V. test can be performed with easily mountable impulse generators. The IEC recommendation for on‐site testing of GIS which is now under discussion doesn't fix the time parameters of the oscillating impulse voltages, but ...
W. Hauschild +3 more
openaire +1 more source
Conference Record of the 2008 IEEE International Symposium on Electrical Insulation, 2008
We developed an Ultra high frequency (UHF) partial discharge fixed and portable monitoring systems to prevent a catastrophic failure of gas-insulated switchgears. The system has been tested in the laboratory and on-site for detection of various tested in the laboratory for detection of various UHF PD signals.
null Chul-min Hwang +3 more
openaire +1 more source
We developed an Ultra high frequency (UHF) partial discharge fixed and portable monitoring systems to prevent a catastrophic failure of gas-insulated switchgears. The system has been tested in the laboratory and on-site for detection of various tested in the laboratory for detection of various UHF PD signals.
null Chul-min Hwang +3 more
openaire +1 more source
The 30th International Conference on Plasma Science, 2003. ICOPS 2003. IEEE Conference Record - Abstracts., 2003
Summary form only given, as follows. In this paper, a novel optical measuring system for the measuring of non-uniform electric field was proposed. The first feasibility investigation on the probe sensor, based on the Pockels cell, has been performed to measure the variation of the electric field due to the corona discharges.
null Ja-yoon Koo +2 more
openaire +1 more source
Summary form only given, as follows. In this paper, a novel optical measuring system for the measuring of non-uniform electric field was proposed. The first feasibility investigation on the probe sensor, based on the Pockels cell, has been performed to measure the variation of the electric field due to the corona discharges.
null Ja-yoon Koo +2 more
openaire +1 more source