Health Indexing for High Voltage Gas-Insulated Switchgear (HVAC GIS)
2018DC systems, Energy conversion ...
openaire +3 more sources
2018 Condition Monitoring and Diagnosis (CMD), 2018
Partial discharge (PD) measurement is performed as one of diagnostic tool for condition monitoring in cubicle-type gas insulated switchgear (C-GIS). This paper presents artificial neural network (ANN) to identify the type of PD occurring in C-GIS. PD measurement results obtained from C-GIS in a field were fed to the ANN as input parameters to determine
Taufik Rossal Sukma +10 more
openaire +1 more source
Partial discharge (PD) measurement is performed as one of diagnostic tool for condition monitoring in cubicle-type gas insulated switchgear (C-GIS). This paper presents artificial neural network (ANN) to identify the type of PD occurring in C-GIS. PD measurement results obtained from C-GIS in a field were fed to the ANN as input parameters to determine
Taufik Rossal Sukma +10 more
openaire +1 more source
Conference Record of the 2008 IEEE International Symposium on Electrical Insulation, 2008
We developed an Ultra high frequency (UHF) partial discharge fixed and portable monitoring systems to prevent a catastrophic failure of gas-insulated switchgears. The system has been tested in the laboratory and on-site for detection of various tested in the laboratory for detection of various UHF PD signals.
null Chul-min Hwang +3 more
openaire +1 more source
We developed an Ultra high frequency (UHF) partial discharge fixed and portable monitoring systems to prevent a catastrophic failure of gas-insulated switchgears. The system has been tested in the laboratory and on-site for detection of various tested in the laboratory for detection of various UHF PD signals.
null Chul-min Hwang +3 more
openaire +1 more source
In-Situ Measurements of SF6 Leak Rates in Indoor Gas-Insulated Switchgears (GIS)
2001All SF6-insulated equipment leaks to some degree. These losses of SF6 gas are usually low and usually less than 2% of the whole gas content of typical GIS. They occur slowly and almost undetected for many years, until a low gas pressure alarm sounds. Over the last fifteen years, manufacturers have continuously improve the gas tightness of their metal ...
openaire +1 more source
Beiträge aus der Plasmaphysik, 1985
AbstractGIS for operation voltages ≧ 245 kV can be tested with oscillating impulse voltages on site advantageously, because this H. V. test can be performed with easily mountable impulse generators. The IEC recommendation for on‐site testing of GIS which is now under discussion doesn't fix the time parameters of the oscillating impulse voltages, but ...
W. Hauschild +3 more
openaire +1 more source
AbstractGIS for operation voltages ≧ 245 kV can be tested with oscillating impulse voltages on site advantageously, because this H. V. test can be performed with easily mountable impulse generators. The IEC recommendation for on‐site testing of GIS which is now under discussion doesn't fix the time parameters of the oscillating impulse voltages, but ...
W. Hauschild +3 more
openaire +1 more source
2019 IEEE Sustainable Power and Energy Conference (iSPEC), 2019
At present, GIS equipment (gas insulated switchgear) is more and more popular in power system, and the detection of GIS faults is mainly aimed at discharging faults. But more and more phenomena show that mechanical faults can not be ignored. In this paper, by analyzing a case of GIS field detection based on ultrasonic and ultrahigh frequency (UHF ...
Qian Wang +5 more
openaire +1 more source
At present, GIS equipment (gas insulated switchgear) is more and more popular in power system, and the detection of GIS faults is mainly aimed at discharging faults. But more and more phenomena show that mechanical faults can not be ignored. In this paper, by analyzing a case of GIS field detection based on ultrasonic and ultrahigh frequency (UHF ...
Qian Wang +5 more
openaire +1 more source
The 30th International Conference on Plasma Science, 2003. ICOPS 2003. IEEE Conference Record - Abstracts., 2003
Summary form only given, as follows. In this paper, a novel optical measuring system for the measuring of non-uniform electric field was proposed. The first feasibility investigation on the probe sensor, based on the Pockels cell, has been performed to measure the variation of the electric field due to the corona discharges.
null Ja-yoon Koo +2 more
openaire +1 more source
Summary form only given, as follows. In this paper, a novel optical measuring system for the measuring of non-uniform electric field was proposed. The first feasibility investigation on the probe sensor, based on the Pockels cell, has been performed to measure the variation of the electric field due to the corona discharges.
null Ja-yoon Koo +2 more
openaire +1 more source
2019 IEEE International Conference on Innovative Research and Development (ICIRD), 2019
This paper represents the relation between moisture content and dew point of SF 6 gas using the Magnus method. The method shows that the main circuit breaker in the high voltage gas insulated switchgear (HVGIS) is the most fragile compartment. The relationship of dew point to moisture content of SF 6 in HVGIS is linear with the rate of change ...
Ratri P. Dewimaruto +4 more
openaire +1 more source
This paper represents the relation between moisture content and dew point of SF 6 gas using the Magnus method. The method shows that the main circuit breaker in the high voltage gas insulated switchgear (HVGIS) is the most fragile compartment. The relationship of dew point to moisture content of SF 6 in HVGIS is linear with the rate of change ...
Ratri P. Dewimaruto +4 more
openaire +1 more source
IEEE Transactions on Dielectrics and Electrical Insulation, 2007
Gas insulated switchgear (GIS) has been increasingly being used in recent years and high reliability and rational insulation design are required. This research provided V-N characteristics (the dielectric breakdown voltage versus number of repetitions characteristics) regarding the internal insulation and creeping insulation of the epoxy spacer, which ...
openaire +1 more source
Gas insulated switchgear (GIS) has been increasingly being used in recent years and high reliability and rational insulation design are required. This research provided V-N characteristics (the dielectric breakdown voltage versus number of repetitions characteristics) regarding the internal insulation and creeping insulation of the epoxy spacer, which ...
openaire +1 more source
2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe), 2023
Diego Mizette Oliz +2 more
openaire +1 more source
Diego Mizette Oliz +2 more
openaire +1 more source