Environmentally friendly compact air-insulated high-voltage substations [PDF]

open access: yes, 2018
This paper investigates the possible options for achieving a substantial reduction in a substation footprint using air-insulated switchgear as a more environmentally-friendly alternative to gas-insulated substations that use SF6 gas.
Albano, Maurizio   +3 more
core   +2 more sources

Regional Court in Brno on Cartels in 2012. Case comments to judgments in CRT cartel and GIS cartel [PDF]

open access: yesYearbook of Antitrust and Regulatory Studies, 2013
In 2012, the Regional Court in Brno has delivered a couple of judgements in two globally notorious cases which were primarily dealt with by the European Commission: the gas insulated switchgear cartel (GIS cartel) and the cathode ray tubes cartel (CRT ...
Petra Joanna Pipková
doaj  

Partial Discharge Measurements in a High Voltage Gas Insulated Transmission Line Insulated with CO2

open access: yesEnergies, 2020
This paper uses practical experimentation to analyse the effect of replacing SF6 with pure CO2 in conventional gas insulated transmission line sections by studying partial discharge measurements taken with applied voltages up to 242 kV (rms). The results
Phillip Widger   +5 more
doaj   +1 more source

A Review on Real-Size Epoxy Cast Resin Insulators for Compact High Voltage Direct Current Gas Insulated Switchgears (GIS) and Gas Insulated Transmission Lines (GIL)—Current Achievements and Envisaged Research and Development [PDF]

open access: yesEnergies, 2020
Due to the ever-increasing demand for electricity in the one hand and the environmental constraints to use clean energy on the other hand, the global production of energy from remote renewable sources, particularly from large hydropower plants and offshore wind farms and their connection to the grid are expected to grow significantly in the future ...
Nabila Zebouchi, Manu. A. Haddad
openaire   +3 more sources

STUDI TENTANG SISTEM INTERLOCKING PADA GAS INSULATED SWITCHGEAR(GIS) 500 KV DI PLTU PAITON UNIT 7 DAN 8 [PDF]

open access: yes, 2010
Electrical energy is one of energy that has the role in all sectors so that the availability of power required by large amount as well as sustainable. PLTU Paiton Unit 7 and 8 is one of the private power company that attempts to meet the high demand for ...
., Jasmadi   +4 more
core  

Boundary element based multiresolution shape optimisation in electrostatics [PDF]

open access: yes, 2015
We consider the shape optimisation of high-voltage devices subject to electrostatic field equations by combining fast boundary elements with multiresolution subdivision surfaces.
Bandara, Kosala   +4 more
core   +1 more source

Nondestructive Measurement of Residual Stress on Epoxy Insulators Using Thermoelastic Method

open access: yesHigh Voltage, EarlyView.
ABSTRACT Residual stress is inevitable in epoxy insulators, which easily leads to small cracks and even insulation breakdown during the operation of gas‐insulated transmission line (GIL)/gas‐insulated switchgear (GIS). This study proposes a nondestructive method to measure the residual stress on epoxy insulators using thermoelastic effects.
Hucheng Liang, Bei Chu, Boxue Du
wiley   +1 more source

The extraction method of evaluation index of safety insulation status of GIS equipment operation based on simplified indicators

open access: yesDiance yu yibiao
Extracting the characteristic indicators of SF6 gas insulated switchgear that reflects equipment insulation status to evaluate its insulation state is the basis for safe operation.
GAO Yibo   +3 more
doaj   +1 more source

SF6 decomposition behaviour under partial discharge of typical insulation defects in gas‐solid insulated valve‐side bushing of converter transformer

open access: yesHigh Voltage, 2023
In this paper we investigated SF6 decomposition behaviour of typical insulation defects in gas‐solid insulated converter transformer valve‐side bushing under partial discharge (PD).
Hongtu Cheng   +6 more
doaj   +1 more source

Quantitative Evaluation of Mechanical Defects for Circuit Breakers Based on Self‐Adaptive Fault Feature Tracking

open access: yesHigh Voltage, EarlyView.
ABSTRACT Many researchers are committed to improving the diagnosis accuracy and solving the few‐shot problem on circuit breakers (CBs). However, the research on the vibration transmission mechanism of the fault is insufficient, which makes it difficult to find the potential design defects of CBs through vibration.
Jiayi Gong   +3 more
wiley   +1 more source