Results 51 to 60 of about 7,327 (250)

Partial Discharge Measurements in a High Voltage Gas Insulated Transmission Line Insulated with CO2

open access: yesEnergies, 2020
This paper uses practical experimentation to analyse the effect of replacing SF6 with pure CO2 in conventional gas insulated transmission line sections by studying partial discharge measurements taken with applied voltages up to 242 kV (rms). The results
Phillip Widger   +5 more
doaj   +1 more source

STUDI TENTANG SISTEM INTERLOCKING PADA GAS INSULATED SWITCHGEAR(GIS) 500 KV DI PLTU PAITON UNIT 7 DAN 8 [PDF]

open access: yes, 2010
Electrical energy is one of energy that has the role in all sectors so that the availability of power required by large amount as well as sustainable. PLTU Paiton Unit 7 and 8 is one of the private power company that attempts to meet the high demand for ...
., Jasmadi   +4 more
core  

A Review on Real-Size Epoxy Cast Resin Insulators for Compact High Voltage Direct Current Gas Insulated Switchgears (GIS) and Gas Insulated Transmission Lines (GIL)—Current Achievements and Envisaged Research and Development [PDF]

open access: yesEnergies, 2020
Due to the ever-increasing demand for electricity in the one hand and the environmental constraints to use clean energy on the other hand, the global production of energy from remote renewable sources, particularly from large hydropower plants and offshore wind farms and their connection to the grid are expected to grow significantly in the future ...
Nabila Zebouchi, Manu. A. Haddad
openaire   +3 more sources

An Improved Fast Computational Method for Vibration Characteristic Analysis of Dry‐Type Iron Core Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT Structural mechanics field simulation plays a critical role in the vibration characteristic analysis of electrical equipment. Existing structural field analysis of equipment based on numerical simulation faces challenges such as convergence difficulties and prolonged computational time, failing to meet the demand for real‐time prediction of ...
Wanqing Wang   +6 more
wiley   +1 more source

Boundary element based multiresolution shape optimisation in electrostatics [PDF]

open access: yes, 2015
We consider the shape optimisation of high-voltage devices subject to electrostatic field equations by combining fast boundary elements with multiresolution subdivision surfaces.
Bandara, Kosala   +4 more
core   +1 more source

Development of ± 550 kV DC GIS Basin Insulator

open access: yesHigh Voltage, EarlyView.
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao   +9 more
wiley   +1 more source

Spectral Characteristics and Evolution Mechanism of Silicon Rubber Surface Discharge Under Thermal Ageing Condition

open access: yesHigh Voltage, Volume 11, Issue 1, Page 192-200, February 2026.
ABSTRACT Surface discharge is a typical fault type in electric power equipment. High temperature in long‐term operation can easily lead to ageing of materials, resulting in changes in surface characteristics and surface discharge faults. In this paper, a method of surface discharge identification of silicon rubber (SiR) based on spectral detection ...
Yanze Han   +6 more
wiley   +1 more source

SF6 decomposition behaviour under partial discharge of typical insulation defects in gas‐solid insulated valve‐side bushing of converter transformer

open access: yesHigh Voltage, 2023
In this paper we investigated SF6 decomposition behaviour of typical insulation defects in gas‐solid insulated converter transformer valve‐side bushing under partial discharge (PD).
Hongtu Cheng   +6 more
doaj   +1 more source

Sifat Dielektrik Campuran Gas CO2 dengan Nitrogen (N2) Dibawah Terpaan Medan Tinggi DC Polaritas Positif [PDF]

open access: yes, 2017
Sulfur hexafluoride gas (SF6) is widely used in the power electrical system such as circuit breaker, gas insulated switchgear (GIS) and gas insulated line (GIL).
Anderson, M. (Michael)   +1 more
core  

Nondestructive Measurement of Residual Stress on Epoxy Insulators Using Thermoelastic Method

open access: yesHigh Voltage, Volume 11, Issue 1, Page 274-283, February 2026.
ABSTRACT Residual stress is inevitable in epoxy insulators, which easily leads to small cracks and even insulation breakdown during the operation of gas‐insulated transmission line (GIL)/gas‐insulated switchgear (GIS). This study proposes a nondestructive method to measure the residual stress on epoxy insulators using thermoelastic effects.
Hucheng Liang, Bei Chu, Boxue Du
wiley   +1 more source