Results 31 to 40 of about 50,705 (207)
A large amount of metal dust is often generated during production and operation of Gas Insulated Switchgear/Gas‐Insulated Transmission Line, and insulating fibres are very easy to mix in during assembly.
Ruixue Liang +4 more
doaj +1 more source
Air gap defects inside a spacer reduce its insulation performance, resulting in stress concentration, partial discharge, and even flashover. If such gap defects are located at the interface between the insulation and conductor, a decrease in mechanical ...
Yuan Deng +6 more
doaj +1 more source
Charge transport and accumulation around the cone-type insulator in SF(6)-filled 550 kV DC GIL
The gas-insulated transmission line (GIL) has the advantages of large transmission capacity, high operation reliability and environmental friendliness. It is suitable for the high voltage direct current (HVDC) power transmission of hydropower stations or
Bo Zhang +5 more
doaj +1 more source
Modelling of Sub-Sea Gas Transmission Pipeline to Predict Insulation Failure [PDF]
Background: Thermally insulated subsea production and transmission systems are becoming more common in deep-water/ offshore operations. Premature failures of the insulation materials for these gas transmission pipelines have had significant operational ...
Dosunmu, A. +3 more
core
A wireless signal transmission technology based on acoustic carrier is proposed, which overcomes the limitation of electromagnetic signal shielding and shows great potential for in‐site monitoring of sliding electrical contact used in gas‐insulated ...
Chen Chen +4 more
doaj +1 more source
Motion Characteristics of Metal Powder Particles in AC GIL and Its Trap Design
In view of the threat of metal particles to the insulation performance of AC GIL (Gas insulated transmission line), this paper uses aluminum powder to simulate the metal particles which are closer to the engineering practice, A scaled-down model similar ...
Zhenyu Zhan +5 more
doaj +1 more source
Power supply for traction substations (TSs) of AC railways has traditionally been provided by 110–220 kV overhead transmission lines (OHL). These OHLs can be damaged during strong winds and ice formation.
Andrey Kryukov +7 more
doaj +1 more source
Tailoring of electron flow current in magnetically insulated transmission lines
It is desirable to optimize (minimizing both the inductance and electron flow) the magnetically insulated vacuum sections of low impedance pulsed-power drivers. The goal of low inductance is understandable from basic efficiency arguments. The goal of low
J. P. Martin +3 more
doaj +1 more source
Technical solutions for the transmission of electricity at high voltage in arctic conditions
The article considers the main solutions to the problems that arise during the transmission of high voltage electricity in the Far North. The relevance of this topic is associated with the high strategic importance of the Arctic zone for the Russian ...
Varivodov V.N. +4 more
doaj +1 more source
TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance
We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching ...
A. Chaudhuri +63 more
core +1 more source