A Review of UHV AC GIL Ex-factory Test Technology
Based on the application of UHV gas-insulated metal-enclosed transmission line(GIL)in the Sutong GIL Utility Tunnel Project, this paper firstly introduces the structural characteristics of UHV GIL, and analyzes its main technical parameters, type test ...
Shuang CHEN +6 more
doaj +1 more source
Simulation and Experiment of SF₆/N₂ Mixed Gas Distribution in High Vertical Drop GIL
Dielectric breakdown of a vertical Gas insulated transmission line (GIL) caused by demixing of the mixture of SF6/N2 is studied by both theoretical simulation and the experimental measure.
Wei Liu, Zhenxi Su, Xinghua Zhang
doaj +1 more source
Designing HVDC GIS/GIL spacer to suppress charge accumulation
To suppress the charge accumulation on the spacer surface in direct current (DC) gas insulated transmission line (GIL) is an important and emergent issue for the development of a clean, safe and economic smart grid.
Zuodong Liang +10 more
doaj +1 more source
Plasma fluorination on epoxy resin surface and its effect on flashover properties
Epoxy resin is the main material of spacer in a gas insulated transmission line and other gas-insulated equipment. During long-term operation, the charge accumulates on the surface of the epoxy resin, which will distort the electric field and thus ...
Zhenyu Zhan +6 more
doaj +1 more source
Green Gas for Grid as an Eco-Friendly Alternative Insulation Gas to SF6: A Review
This paper deals with a review of the state-of-the-art performance investigations of green gas for grid (g3) gas, which is an emerging eco-friendly alternative insulation gas for sulfur hexafluoride (SF6) that will be used in gas-insulated power ...
Baofeng Pan +5 more
doaj +1 more source
China’s 10-year progress in DC gas-insulated equipment: From basic research to industry perspective
The construction of the future energy structure of China under the 2050 carbon-neutral vision requires compact direct current (DC) gas-insulation equipment as important nodes and solutions to support electric power transmission and distribution of long ...
Chuanyang Li +26 more
doaj +1 more source
Evaluation of SF6 Leakage from Gas Insulated Equipment on Electricity Networks in Great Britain
This paper examines the data collected from the power industry over the last six years of actual reported emissions of sulphur hexafluoride (SF6) and the potential impact.
Phillip Widger +1 more
doaj +1 more source
Outdoor Insulation and Gas Insulated Switchgears
This book focuses on theoretical and practical developments in the performance of high-voltage transmission line against atmospheric pollution and icing.
core +1 more source
Charge accumulation has always been a problem for the safe operation of gas insulated switchgear (GIS)/gas insulated transmission line (GIL) both under AC and DC.
Dayu Li +4 more
doaj +1 more source
Seismic Performance Evaluation and Retrofit Strategy of Overhead Gas-Insulated Transmission Lines
The overhead gas-insulated transmission line (GIL) in ultra-high-voltage converter stations, distinct from traditional buried pipelines, demands a thorough investigation into its seismic behavior due to limitations in existing codes.
Xiaoxuan Li, Qiang Xie, Jiayi Wen