Results 61 to 70 of about 1,517 (163)
Based on a multi‐dimensional diagram model, a technique for visual verification of the risk of starting substation equipment is studied. This method can effectively and precisely verify the possible risks during the substation equipment startup and enhance the power system's operational safety.
Lifan Mao +4 more
wiley +1 more source
The Ultra-High Frequency (UHF) method is widely used for live detection of partial discharge in GIS (Gas Insulated Switchgear). To ensure the accuracy of the detection results, it is necessary to regularly calibrate the performance of UHF sensors ...
Tian Tian +7 more
doaj +1 more source
An overview of biodiesel energy [PDF]
Over the last ten years’ attention to biofuels production has increased dramatically and become crucial. One of the main factors is the rise in world oil prices, coupled with the abatement of greenhouse gas emissions and concerns about energy security ...
Abd Halim, Muhamad Fazli +3 more
core
ABSTRACT There is a need to develop an improved insulating material that surpasses traditional insulators in terms of insulation and efficient operation under extreme weather conditions. Epoxy nanocomposites (NCs) have gained considerable attention due to their intrinsic material properties.
Abubakar Siddique +7 more
wiley +1 more source
Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages [PDF]
The high reliability and safety provided by the compressed gas insulated substations(CGIS) has proved that the they are more advantageous than the conventional air insulated substations. All the parts of the GIS are enclosed in metal enclosures which are
Reddy, P.Nagarjuna, S.S.Tulasiram
core +1 more source
Abstract Mechanical vibration defect is the key factor leading to sudden failure of gas‐insulated switchgear (GIS) equipment. It is important to realise effective prediction of the mechanical vibration state development trend of GIS equipment in order to improve its active safety protection level.
Xu Li +5 more
wiley +1 more source
Best practices and informal guidance on how to implement the Comprehensive Assessment at Member State level [PDF]
This report details a methodology for performing a cost-benefit analysis (CBA) identifying the most resource and cost-efficient solutions to meet heating and cooling demands for a given country or region in accordance with Article 14(3) and taking in ...
CARLSSON Johan +5 more
core +1 more source
A novel GIS breakdown location method based on natural frequency of transient voltage
Abstract During on‐site withstand voltage tests of gas‐insulated switchgears (GIS), once a breakdown occurs, it is hard to locate the breakdown position due to the intricate branch structures and minimal breakdown energy. The existing methods may require the placement of a large number of sensors with unsatisfactory accuracy, which adversely affects ...
Qiang Sun +9 more
wiley +1 more source
Analysis of Electric Field Intensity in Gas Insulated Busduct [PDF]
Gas insulated substations (GIS) have received great interest in the recent years. One of the advantages of GIS over conventional substations is their compactness which makes them a favourite for service in urban residential areas.
D. Subbarayudu, J. Amarnath
core
Abstract Partial discharge (PD) detection is considered one of the most crucial and effective methods for identifying defects in electrical equipment. Consequently, investigating advanced and efficient PD monitoring techniques is essential for the development of gas‐insulated equipment (GIE) and the construction of ultra‐high‐voltage (UHV) networks ...
Xianhao Fan +15 more
wiley +1 more source