Results 61 to 70 of about 1,517 (163)

A Visualization Verification Method for Startup Risk of Substation Equipment Based on Multidimensional Graph Models

open access: yesEngineering Reports, Volume 7, Issue 11, November 2025.
Based on a multi‐dimensional diagram model, a technique for visual verification of the risk of starting substation equipment is studied. This method can effectively and precisely verify the possible risks during the substation equipment startup and enhance the power system's operational safety.
Lifan Mao   +4 more
wiley   +1 more source

Simulation Study on the Calibration of UHF Sensor for GIS Partial Discharge Detection Based on Noise Interference

open access: yesIEEE Access
The Ultra-High Frequency (UHF) method is widely used for live detection of partial discharge in GIS (Gas Insulated Switchgear). To ensure the accuracy of the detection results, it is necessary to regularly calibrate the performance of UHF sensors ...
Tian Tian   +7 more
doaj   +1 more source

An overview of biodiesel energy [PDF]

open access: yes, 2020
Over the last ten years’ attention to biofuels production has increased dramatically and become crucial. One of the main factors is the rise in world oil prices, coupled with the abatement of greenhouse gas emissions and concerns about energy security ...
Abd Halim, Muhamad Fazli   +3 more
core  

Influence of Nanoparticles on Dielectric Properties of High‐Voltage Epoxy‐Based Nanocomposite Insulators: Simulation and Experimental Analysis

open access: yesEnergy Science &Engineering, Volume 13, Issue 11, Page 5605-5626, November 2025.
ABSTRACT There is a need to develop an improved insulating material that surpasses traditional insulators in terms of insulation and efficient operation under extreme weather conditions. Epoxy nanocomposites (NCs) have gained considerable attention due to their intrinsic material properties.
Abubakar Siddique   +7 more
wiley   +1 more source

Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages [PDF]

open access: yes, 2018
The high reliability and safety provided by the compressed gas insulated substations(CGIS) has proved that the they are more advantageous than the conventional air insulated substations. All the parts of the GIS are enclosed in metal enclosures which are
Reddy, P.Nagarjuna, S.S.Tulasiram
core   +1 more source

Mechanical vibration state and its defect severity development trend prediction for gas‐insulated switchgear equipment: Attention‐bidirectional gated recurrent unit model construction and experimental verification

open access: yesHigh Voltage, Volume 10, Issue 4, Page 831-844, August 2025.
Abstract Mechanical vibration defect is the key factor leading to sudden failure of gas‐insulated switchgear (GIS) equipment. It is important to realise effective prediction of the mechanical vibration state development trend of GIS equipment in order to improve its active safety protection level.
Xu Li   +5 more
wiley   +1 more source

Best practices and informal guidance on how to implement the Comprehensive Assessment at Member State level [PDF]

open access: yes, 2015
This report details a methodology for performing a cost-benefit analysis (CBA) identifying the most resource and cost-efficient solutions to meet heating and cooling demands for a given country or region in accordance with Article 14(3) and taking in ...
CARLSSON Johan   +5 more
core   +1 more source

A novel GIS breakdown location method based on natural frequency of transient voltage

open access: yesHigh Voltage, Volume 10, Issue 4, Page 856-875, August 2025.
Abstract During on‐site withstand voltage tests of gas‐insulated switchgears (GIS), once a breakdown occurs, it is hard to locate the breakdown position due to the intricate branch structures and minimal breakdown energy. The existing methods may require the placement of a large number of sensors with unsatisfactory accuracy, which adversely affects ...
Qiang Sun   +9 more
wiley   +1 more source

Analysis of Electric Field Intensity in Gas Insulated Busduct [PDF]

open access: yes
Gas insulated substations (GIS) have received great interest in the recent years. One of the advantages of GIS over conventional substations is their compactness which makes them a favourite for service in urban residential areas.
D. Subbarayudu, J. Amarnath
core  

A review of advanced acoustic‐chemical‐optical partial discharge monitoring techniques for ultra‐high‐voltage gas‐insulated equipment

open access: yesHigh Voltage, Volume 10, Issue 4, Page 787-806, August 2025.
Abstract Partial discharge (PD) detection is considered one of the most crucial and effective methods for identifying defects in electrical equipment. Consequently, investigating advanced and efficient PD monitoring techniques is essential for the development of gas‐insulated equipment (GIE) and the construction of ultra‐high‐voltage (UHV) networks ...
Xianhao Fan   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy