Design and Application of a Metamaterial Superstrate on a Bio-Inspired Antenna for Partial Discharge Detection through Dielectric Windows. [PDF]
Xavier GVR +5 more
europepmc +1 more source
Design and Development of a Bio-Inspired UHF Sensor for Partial Discharge Detection in Power Transformers. [PDF]
Nobrega LAMM +5 more
europepmc +1 more source
Partial Discharge Detection Using a Spherical Electromagnetic Sensor. [PDF]
Romano P, Imburgia A, Ala G.
europepmc +1 more source
On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation. [PDF]
Albarracín R, Ardila-Rey JA, Mas'ud AA.
europepmc +1 more source
Characterization of Partial Discharges in Dielectric Oils Using High-Resolution CMOS Image Sensor and Convolutional Neural Networks. [PDF]
Monzón-Verona JM +2 more
europepmc +1 more source
Related searches:
Partial discharge in Gas Insulated substations (GIS): A development and engineering perspective
2013 12th International Conference on Environment and Electrical Engineering, 2013GIS and its allied subsystems are always expected to function and work with extremely high level of reliability. These substations contain several dielectric interfaces and combinational insulating medias. The GIS may be subject to Partial discharge activity may initiate in some conditions in the GIS modules considering its varied operating conditions ...
V. Aaradhi, K. Gaidhani
exaly +2 more sources
Comparison Between Suppressing Approaches of Very Fast Transients in Gas-Insulated Substations (GIS)
IEEE Transactions on Power Delivery, 2013In this paper, first transient waves in the gas-insulated substation (GIS) are analyzed and methods for suppression of very fast transients (VFTs) in GISs are introduced. For suppressing VFTs, four methods are presented, including suppression by terminal components, capacitance components, adopting a resistor-fitted disconnector, and ferromagnetic ...
Hassan Nouri, Michael Negnevitsky
exaly +2 more sources
The Insulation Performance of Compressed Gas Insulated Switchgear and Gas Insulated Transmission Line(GITL) systems can be substantially affected by the presence and movement of metallic particle contaminants. SF 6 gas is the main mode of insulation in Gas Insulated Substations(GIS).
J Amarnath
exaly +2 more sources
Marcos Tello +2 more
exaly +2 more sources
Reliable and economical power transmission and distribution are key functions for the future electric power supply. Gas insulated switchgear is used in industrial areas to fulfil high-energy demands by space saving design with a minimum of cost. Only SF6 insulated switchgear is able to fulfil these requirements.
P. Bolin, H. Koch
openaire +1 more source