Optimization of Maintenance Scheduling and Task Clustering in Gas-Insulated Substations
International audienceGas-Insulated Substations (GIS) are compact and highly reliable electrical substations widelydeployed in modern power systems, where key high-voltage components are enclosed withinsealed metal compartments filled with sulfur ...
Kaddah, Rim +4 more
core
During the last 40 years, Gas Insulated Switchgear technology has evolved. The years 2020’s, will see another major turn in the GIS evolution with a new type of technology using alternative gas to SF6.
Michael Inversin +3 more
core
New Synthetic Partial Discharge Calibrator for Qualification of Partial Discharge Analyzers for Insulation Diagnosis of HVDC and HVAC Grids. [PDF]
Khamlichi A, Garnacho F, Simón P.
europepmc +1 more source
A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations [PDF]
This thesis investigates the feasibility of a new method to prevent internal resonance in transformers connected to gas insulated substation due to very fast transient overvoltage in the GIS.
Babaeilaktarashani, Mehdi
core
Comparative analysis and evaluation of a case study of conventional and gas-insulated substations
Este trabalho tem como objetivo destacar elementos relevantes de uma análise comparativa entre subestações convencionais e isoladas a gás (GIS). As subestações são componentes essenciais no sistema de transmissão e distribuição de energia elétrica, e a ...
Celeri, Heitor Berger [UNESP]
core
LAUREA MAGISTRALENelle sottostazioni isolate in gas (Gas-Insulated Switchgear, GIS), a causa di guasti a terra o a causa delle manovre di interruttori e sezionatori, possono verificarsi dei transitori veloci di tensione (Very Fast Transient Overvoltage,
CHEN, SHU
core
An Acoustic Localization Sensor Based on MEMS Microphone Array for Partial Discharge. [PDF]
Yan J, Chen C, Wu Z, Ding X, Lou L.
europepmc +1 more source
A Comparison of Partial Discharge Sensors for Natural Gas Insulated High Voltage Equipment. [PDF]
Widger P, Carr D, Hills M, Reid A.
europepmc +1 more source
One-Shot Learning for Partial Discharge Diagnosis Using Ultra-High-Frequency Sensor in Gas-Insulated Switchgear. [PDF]
Tuyet-Doan VN +5 more
europepmc +1 more source
Quality Control Approach for the Detection of Internal Lower Density Areas in Composite Disks in Industrial Conditions Based on a Combination of NDT Techniques. [PDF]
Katunin A +3 more
europepmc +1 more source

