Results 1 to 10 of about 43,708 (186)
Unsteady heat transfer of long gas insulated transmission lines in tunnel: Model and analysis [PDF]
The temperature of the cable core and cable casing is crucial for the safety and efficiency of the transmission system. Accurately predicting the distribution and variation of the transmission temperature field in the gas insulated transmission lines ...
Guo Li +4 more
doaj +2 more sources
Metal particle contamination in gas-insulated switchgears/gas-insulated transmission lines
Jian Wang +7 more
doaj +2 more sources
Environment-friendly insulating gases for HVDC gas-insulated transmission lines
Geng Chen +8 more
doaj +3 more sources
The implementation of stranded conductors in flexible gas-insulated transmission lines (FGILs) requires field intensity minimization as well as field irregularity suppression in order to avoid dielectric breakdown.
Muhammad Junaid Alvi +4 more
doaj +2 more sources
Flashover at gas/insulator interface acts as a vital challenge to the safe and stable operation of gas-insulated system especially when involved with surface metallic particle.
Xiaolong Li, Chen Cao, Xin Lin
doaj +1 more source
Seismic Performance Evaluation and Retrofit Strategy of Overhead Gas-Insulated Transmission Lines
The overhead gas-insulated transmission line (GIL) in ultra-high-voltage converter stations, distinct from traditional buried pipelines, demands a thorough investigation into its seismic behavior due to limitations in existing codes.
Xiaoxuan Li, Qiang Xie, Jiayi Wen
doaj +1 more source
Experimental Results of Partial Discharge Localization in Bounded Domains
This work presents a novel diagnostic method to localize Partial Discharges (PDs) inside Medium Voltage (MV) and High Voltage (HV) equipment. The method is well suited for that equipment presenting a bounded domain with fixed Boundary Conditions (BCs ...
Luca Perfetto, Gabriele D’Antona
doaj +1 more source
Due to the ever-increasing demand for electricity in the one hand and the environmental constraints to use clean energy on the other hand, the global production of energy from remote renewable sources, particularly from large hydropower plants and ...
Nabila Zebouchi, Manu. A. Haddad
doaj +1 more source
Partial discharge (PD) is one of the main causes rendering the deterioration of the insulation state in gas‐insulated transmission line (GIL). Accurate and timely localization of the PD source is essential to ensure the safe and stable operation of the ...
Yiming Zang +5 more
doaj +1 more source
Herein, the surface charge characteristics of a tri‐post insulator in a ± 500 kV direct current gas‐insulated transmission lines (DC‐GIL) filled with SF6 are thoroughly studied.
Xiaolong Li +5 more
doaj +1 more source