Results 101 to 110 of about 64,212 (257)
We describe an extension to the Geant4 software package that allows it to be used as a general purpose X-ray tracing package. We demonstrate its use by building a model of the X-ray optics of the XMM-Newton, calculating its effective area, and comparing ...
Agostinelli +8 more
core +1 more source
G4CMP: Condensed matter physics simulation using the Geant4 toolkit [PDF]
M. Kelsey +46 more
semanticscholar +1 more source
Perovskite CsPbBr3 nanocrystals exhibit bright emission, fast response, and solution processability, but their nanoscale size limits efficient radiation detection. Organizing them into porous SiO2 mesospheres enhances radioluminescence up to 40 times, achieving an optimal combination of light yield, fast scintillation, and processability, providing a ...
Xiaohe Zhou +14 more
wiley +1 more source
The Geant4 Bertini Cascade [PDF]
One of the medium energy hadron–nucleus interaction models in the Geant4 simulation toolkit is based partly on the Bertini intranuclear cascade model. Since its initial appearance in the toolkit, this model has been largely re-written in order to extend its physics capabilities and to reduce its memory footprint. Physics improvements include extensions
Wright, D.H., Kelsey, M.H.
openaire +1 more source
Abstract Background The Xoft electronic brachytherapy source is commonly used to treat superficial lesions and tumors located at shallow depths. However, uncertainties in material composition and geometry, mainly arising due to the manual assembly of the x‐ray tube components, contribute to inter‐source variability in the tube output spectrum.
Azin Esmaelbeigi +6 more
wiley +1 more source
Validation of Geant4-based Radioactive Decay Simulation
Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required.
Batič, Matej +9 more
core +1 more source
Abstract Purpose To develop clinically relevant test cases for commissioning Model‐Based Dose Calculation Algorithms (MBDCAs) for 192Ir High Dose Rate (HDR) gynecologic brachytherapy following the workflow proposed by the TG‐186 report and the WGDCAB report 372.
Vasiliki Peppa +6 more
wiley +1 more source
Re-engineering a nanodosimetry Monte Carlo code into Geant4: software design and first results
A set of physics models for nanodosimetry simulation is being re-engineered for use in Geant4-based simulations. This extension of Geant4 capabilities is part of a larger scale R&D project for multi-scale simulation involving adaptable, co-working ...
Gargioni, E., Grichine, V., Pia, M. G.
core +1 more source
Abstract Context. The Electron Proton Helium INstrument (EPHIN) aboard SOlar and Heliospheric Observatory is a particle telescope that measures energetic protons and helium above 4 MeV/nuc and electrons above 150 keV. While a calibration of EPHIN has been performed before launch, it has only partially been assessed reducing the accuracy of the detector
M. Hörlöck +4 more
wiley +1 more source
Research and Development of a Natural Radioactivity Detection System for Import and Export Goods
China imports a large amount of bulk minerals and rare metals every year,and during customs radiation monitoring,harmless alarms are often triggered due to the presence of natural radioactive elements (NORM) in the minerals.
Jian ZHAN +8 more
doaj +1 more source

