Evaluation of Time-Critical Communications for IEC 61850-Substation Network Architecture
International audiencePresent-day developments, in electrical power transmission and distribution, require considerations of the status quo. In other meaning, international regulations enforce increasing of reliability and reducing of environment impact,
Altaher, Ahmed +2 more
core
Scenarios for the development of smart grids in the UK: literature review [PDF]
Smart grids are expected to play a central role in any transition to a low-carbon energy future, and much research is currently underway on practically every area of smart grids.
Axon, Colin +8 more
core +2 more sources
Experimental Evaluation of an IEC 61850-Station Bus Communication Reliability
National audienceRecent improvements, in electrical power transmission and distribution, require considerations of existing regulations that enforce increasing of reliability and reducing of environment impact.
Altaher, Ahmed +2 more
core +1 more source
Corrupted GOOSE Detectors: Anomaly Detection in Power Utility Real-Time Ethernet Communications
International audienceGOOSE protocol is used for critical protection operations in the power grid, as standardized by IEC61850. It thus has strong real-time constraints that make very hard to implement any security means for integrity and confidentiality
Bellemain, Pascal +4 more
core +1 more source
[Objective] To enable accurate determination of DC (direct current) bus overcurrent protection in metro DC traction power supply system and enhance the selectivity of fault tripping in the system, the research on a suitable DC bus overcurrent protection ...
LIU Yuxing +5 more
doaj +1 more source
Modeling and simulation of IEC 61850 requirements applied to an automated people mover's controller [PDF]
Automated People Movers (APM) are systems for passenger transport with fully automated operation and high frequency service. For this study, we proposed the adaptation of the standard IEC 61850 (design to be used in electric power systems based in ...
Kunz, Guilherme +2 more
core
Performance Analysis of Routable GOOSE Security Algorithm for Substation Communication through Public Internet Network. [PDF]
Shin S, Yang H.
europepmc +1 more source
A Study on the Fault Location of Secondary Equipment in Smart Substation Based on the Graph Attention Network. [PDF]
Xiang XM +4 more
europepmc +1 more source
Methodology of the direct measurement of the switching latency [PDF]
The article provides a measurement methodology based on the related RFCs. It brings a solution of determining the switching latency on the physical layer using common measuring devices.
Boháč, Leoš +4 more
core
Towards Latency Bypass and Scalability Maintain in Digital Substation Communication Domain with IEC 62439-3 Based Network Architecture. [PDF]
Tightiz L, Yoo J.
europepmc +1 more source