Results 181 to 190 of about 7,176,145 (231)
Some of the next articles are maybe not open access.
High Voltage, 2020
In this study, a simulation model of surface charge accumulation has been established. The model considers three accumulation ways, i.e. electrical conduction within the gas, through insulator volume and along the insulator surface.
Yi Luo +5 more
semanticscholar +1 more source
In this study, a simulation model of surface charge accumulation has been established. The model considers three accumulation ways, i.e. electrical conduction within the gas, through insulator volume and along the insulator surface.
Yi Luo +5 more
semanticscholar +1 more source
Conductor Surface Roughness-dependent Gas Conduction Process for HVDC GIL—Part II: Experiment
IEEE transactions on dielectrics and electrical insulation, 2021In this paper, an electric field ranging from 0.44-5.24 kV/mm was applied to a gas-insulated line (GIL) model filled with SF6 at different values of gas pressure and relative humidity (RH).
Chuanyang Li +11 more
semanticscholar +1 more source
Mechanical Stress Distribution and Reliability Analysis of GIL Tri-post Insulator
International Conference on Electrical Materials and Power Equipment, 2021Tri-post insulator is the key insulation component of UHV and EHV gas insulated transmission pipeline (GIL), and its mechanical reliability is directly related to the operation safety of GIL.
Songtao Liu +5 more
semanticscholar +1 more source
IEEE transactions on dielectrics and electrical insulation, 2020
In this paper, the surface nonlinear conductivity (SNC) spacer is proposed to regulate the electric field in a 500 kV DC-GIL, whose effects are verified by assigning a temperature gradient, a rough electrode, a metal particle and a polarity reversal ...
H. C. Liang, B. Du, J. Li
semanticscholar +1 more source
In this paper, the surface nonlinear conductivity (SNC) spacer is proposed to regulate the electric field in a 500 kV DC-GIL, whose effects are verified by assigning a temperature gradient, a rough electrode, a metal particle and a polarity reversal ...
H. C. Liang, B. Du, J. Li
semanticscholar +1 more source
High-Resolution Temperature Distribution Measurement of GIL Spacer Based on OFDR and Ultraweak FBGs
IEEE Transactions on Instrumentation and Measurement, 2020The temperature distribution on the gas-insulated line (GIL) spacer affects surface charge accumulation. However, the spacer temperature distribution is hard to measure because the conventional electric sensors are large dimensions, hard to multiplex ...
G. Ma +6 more
semanticscholar +1 more source
Effects of surface conductivity on surface charging behavior of DC-GIL spacers
IEEE transactions on dielectrics and electrical insulation, 2020In this study, a simulation model is established to study the effect of surface conductivity on the accumulation of surface charge. The simulation shows that hetero-charges increase on areas away from the high voltage electrode and the electric field ...
Junhong Chen +5 more
semanticscholar +1 more source
Electrical field distribution along SG6/N2 filled DC-GIS/GIL epoxy spacer
IEEE transactions on dielectrics and electrical insulation, 2018The flashover faults due to the accumulation of surface charge have restricted the further development of spacers in HVDC GIS/GIL transmission systems.
B. Du, H. C. Liang, J. Li, Z. Ran
semanticscholar +1 more source
IEEE Transactions on Reliability, 2019
Confronted with the ever-growing demand for electricity delivery over long distances, the gas insulated transmission line (GIL), as an advanced underground technology, has been under rapid development recently.
Songhua Hao, Jun Yang
semanticscholar +1 more source
Confronted with the ever-growing demand for electricity delivery over long distances, the gas insulated transmission line (GIL), as an advanced underground technology, has been under rapid development recently.
Songhua Hao, Jun Yang
semanticscholar +1 more source
Improved Method for Acoustic Identification of Free Conductive Particle Defects in GIL
IEEE Transactions on Power Delivery, 2019The presence of free conductive particles in gas-insulated transmission lines (GIL) is the most significant threat to their insulation. The non-invasive identification of free conductive particle defects in GILs is extremely challenging.
Zhicheng Wu +3 more
semanticscholar +1 more source