Results 191 to 200 of about 1,703,695 (249)
Some of the next articles are maybe not open access.

Glucose oxidase of Phanerochaete chrysosporium

1988
Publisher Summary Glucose oxidase catalyzes the oxidation of D-glucose to δ-D-gluconolactone and H 2 O 2 in the presence of molecular oxygen. In a subsequent step δ -D-gluconolactone is nonenzymatically hydrolyzed to D-gluconic acid. This enzyme has been demonstrated in various Aspergillus and Penicillium species and has recently been purified ...
R L, Kelley, C A, Reddy
openaire   +2 more sources

Glucose oxidase?magnetite nanoparticle bioconjugate for glucose sensing

Analytical and Bioanalytical Chemistry, 2004
Immobilization of bioactive molecules on the surface of magnetic nanoparticles is of great interest, because the magnetic properties of these bioconjugates promise to greatly improve the delivery and recovery of biomolecules in biomedical applications.
Liane M, Rossi   +2 more
openaire   +2 more sources

Glucose Biosensor Using Glucose Oxidase Immobilized in Polyaniline

Applied Biochemistry and Biotechnology, 1992
A biosensor for glucose utilizing kinetics of glucose oxidase (EC 1.1.3.4.) was developed. The enzyme was immobilized on polyaniline by covalent bonding, using glutaraldehyde as a bifunctional agent. The system showed a linear response up to 2.2 mM of glucose with a response time of 2.5-4.0 min. In addition, the immobilized enzyme had a higher activity
A H, Parente   +5 more
openaire   +2 more sources

Glucose Oxidase Multilayer Modified Microcantilevers for Glucose Measurement

Analytical Chemistry, 2005
We report a novel enzyme-based microcantilever sensor by using layer-by-layer nanoassembly modification. A glucose oxidase (GOx) functionalized microcantilever underwent bending when it was exposed to glucose solutions. The magnitudes of bending were proportional to the concentrations of glucose.
Xiaodong, Yan   +2 more
openaire   +2 more sources

Glucose oxidase immobilized polyethylene‐g‐acrylic acid membrane for glucose oxidase sensor

Biotechnology and Bioengineering, 1990
AbstractA polyethylene‐g‐acrylic acid (PE‐g‐AA) graft copolymer was prepared via gamma‐ray‐irradiation‐induced postirradiation procedures, and was used as support material for the immobilization of glucose oxidase. Soluble carbodiimides were used as the coupling agent. Reasonable yields were obtained with CMC but not with EDAC, EEDQ, or WRK.
G H, Hsiue, C C, Wang
openaire   +2 more sources

Glucose sensor with immobilized glucose oxidase-glucose isomerase membrane

Journal of Molecular Catalysis, 1981
Abstract A glucose sensor, i.e., an oxygen detection electrode with immobilized glucose oxidase, has been studied by several researchers as a novel analytical technique which can simplify tedious steps in conventional methods of glucose determination. In a glucose sensor of such construction, any glocuse oxidase inhibition will impair the performance
Shinichiro Gondo   +2 more
openaire   +1 more source

Glucose concentration measurement using immobilized glucose oxidase

Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1989
Abstract A reactor with an immobilized glucose oxidase layer on a magnetic disc impeller for routine determination of the glucose concentration in biological samples was designed and studied both experimentally and theoretically. The rate of oxygen concentration decrease in the reacting mixture (consisting of ca.
K. Špirko, V. Linek, J. Čerkasov
openaire   +1 more source

A high-throughput colorimetric assay for glucose detection based on glucose oxidase-catalyzed enlargement of gold nanoparticles.

Nanoscale, 2015
We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs).
Yanmei Xiong   +5 more
semanticscholar   +1 more source

Interference in glucose oxidase-peroxidase blood glucose methods

Clinica Chimica Acta, 1972
Abstract Interference by certain compounds with the glucose oxidase-peroxidase system used in blood glucose estimations appears to be a function of the oxygen affinity of the oxygen acceptor chromogen or the oxidative coupling system. It has been shown 1 that tolazamide interferes seriously with the Boehringer GOD-PERID blood glucose method.
openaire   +2 more sources

Glucose oxidase immobilized electrode for potentiometric estimation of glucose

Biosensors and Bioelectronics, 1991
Glucose oxidase has been immobilized onto a thin platinum strip, by co-crosslinking with bovine serum albumin and glutaraldehyde. The retention of redox characteristics of glucose oxidase has been verified by cyclic voltammetry. The activity of the immobilized enzyme reduces to a quarter of its value when the enzyme is in solution but improves when ...
S, Alva   +3 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy