Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo +5 more
doaj +5 more sources
Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry [PDF]
Purpose: The aim of this study was to compare the intraocular pressure measurements obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry, and Goldmann applanation tonometry in different age groups.
Goktug Demirci +4 more
doaj +5 more sources
Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis +5 more
doaj +2 more sources
Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus [PDF]
Maddalena De Bernardo, Nicola Rosa
doaj +4 more sources
Comparison of Non-contact Tonometry and Goldmann Applanation Tonometry Measurements in Non-pathologic High Myopia [PDF]
PurposeTo compare intraocular pressure (IOP) values obtained using Goldmann applanation tonometry (IOPGAT) and non-contact tonometry (IOPNCT) in a non-pathologic high myopia population.MethodsA total of 720 eyes from 720 Chinese adults with non ...
Peiyuan Wang +10 more
doaj +2 more sources
Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry [PDF]
PurposeTo evaluate the accuracy of the new Tono-Vera rebound tonometer (Reichert Inc, Buffalo, NY) compared to Goldmann Applanation Tonometry.MethodsThis prospective, observational, cross-sectional study was designed in accordance with ANSI Z80.10-2014 ...
Charles R. Niles +3 more
doaj +2 more sources
Using Deep Learning to Automate Goldmann Applanation Tonometry Readings. [PDF]
To develop an objective and automated method for measuring intraocular pressure using deep learning and fixed-force Goldmann applanation tonometry (GAT) techniques.Prospective cross-sectional study.Patients from an academic glaucoma practice.Intraocular pressure was estimated by analyzing videos recorded using a standard slit-lamp microscope and fixed ...
Spaide T +9 more
europepmc +4 more sources
Background. To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) following trabeculectomy. Methods. Thirty eight glaucomatous eyes with a history of trabeculectomy (Trabeculectomy group, TG), 20 eyes ...
Efstathios T. Detorakis +3 more
doaj +3 more sources
Comparison of ICare and IOPen vs Goldmann applanation tonometry according to international standards 8612 in glaucoma patients [PDF]
AIM: To compare IOPen and ICare rebound tonometry to Goldmann applanation tonometry (GAT) according to International Standards Organization (ISO) 8612 criteria. METHODS: Totally 191 eyes (n=107 individuals) were included.
Milena Pahlitzsch +6 more
doaj +2 more sources
Purpose: To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal ...
Fatih Özcura +3 more
doaj +3 more sources