Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo [PDF]
Background Goldmann applanation tonometry (GAT) error relative to intracameral intraocular pressure (IOP) has not been examined comparatively in both human cadaver eyes and in live human eyes.
Sean McCafferty +3 more
doaj +2 more sources
Anne Herr,1 Andreas Remky,2 Thalia Hirsch,1 Corinna Rennings,1 Niklas Plange1 1Department of Ophthalmology, RWTH Aachen University, Aachen, Germany; 2Augenbelegabteilung Krankenhaus Barmherzige Brueder, Regensburg, Germany Introduction: Intraocular ...
Herr A +4 more
doaj +5 more sources
Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature [PDF]
Konstantinos Andreanos, Chryssanthi Koutsandrea, Dimitris Papaconstantinou, Andreas Diagourtas, Andreas Kotoulas, Panagiotis Dimitrakas, Marilita M Moschos First Department of Ophthalmology, University of Athens, “G.
Andreanos K +6 more
doaj +2 more sources
Comparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs [PDF]
Background and Aim: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement ...
João Victor Goulart Consoni Passareli +6 more
doaj +1 more source
Intraocular Pressure Measurement after Penetrating Keratoplasty
Assessing the intraocular pressure is a difficult but crucial task in the follow-up of patients that have undergone penetrating keratoplasty. Early recognition of elevated intraocular pressure and/or glaucoma and establishment of the appropriate ...
Otilia-Maria Dumitrescu +3 more
doaj +1 more source
Comparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry [PDF]
To compare the intraocular pressures (IOPs) measured by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT), and to investigate the association of IOPs on eyes of varying central corneal thickness (CCT).In this prospective study, 451 eyes of 233 subjects were enrolled. IOPs were measured by GAT and DCT. CCT was measured three times
Lee, Jooeun +6 more
openaire +2 more sources
Initial experience in self-monitoring of intraocular pressure. [PDF]
Background/aims: Diurnal variation in intraocular pressure (IOP) is a routine assessment in glaucoma management. Providing patients the opportunity to perform self-tonometry might empower them and free hospital resource.
Dabasia, P. +4 more
core +2 more sources
Goldmann applanation tonometry after myopic photorefractive keratectomy [PDF]
To determine the accuracy of applanation tonometry in patients with corneas thinned by photorefractive keratectomy, and to correlate corneal changes with tonometric readings.The intraocular pressure was measured with Goldmann applanation tonometry in 87 patients who underwent photorefractive keratectomy before and 1, 6 and 12 months after treatment ...
Rosa N +3 more
openaire +4 more sources
Comparison of Goldmann applanation tonometry and Icare tonometry
AbstractPurposeTo compare the variation of intraocular pressure (IOP) measured with Goldmann applanation tonometry (GAT) and Icare tonometry, and further determine if the two methods were calibrated to each other.MethodsTotally 20 subjects within normal IOP range were evenly divided into two method groups.
Zhaohua Yu +3 more
openaire +1 more source
Goldmann Tonometry and Corneal Biomechanics
Glaucoma is the second cause of irreversible blindness in the world. Intraocular pressure (IOP) is a recognized major risk factor for the development and progression of glaucomatous damage. Goldmann applanation tonometry (GAT) is internationally accepted
Dario Messenio +2 more
doaj +1 more source