International comparisons of intraocular pressures, as measured by Tono-Pen and Goldmann applanation tonometry, in healthy adults: A meta-analysis. [PDF]
Keller WJ.
europepmc +2 more sources
iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre. [PDF]
Quérat L, Chen E.
europepmc +3 more sources
Pascal, ICare and Goldmann applanation tonometry – a comparative study [PDF]
Abstract.Purpose: To compare intraocular pressure (IOP) measurements by Pascal, ICare and Goldmann applanation tonometry (GAT), to evaluate the effects of central corneal thickness (CCT) and curvature on IOP measurement and to estimate the intra‐observer variability.Methods: A prospective, single‐centre study of 150 eyes with a wide range of ...
Gauti Jóhannesson +3 more
openalex +3 more sources
Comparison of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes [PDF]
AIM: To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in normal and glaucomatous eyes and investigate the effects of central corneal ...
Fatih Özcura +4 more
doaj +2 more sources
Background. To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) following trabeculectomy. Methods. Thirty eight glaucomatous eyes with a history of trabeculectomy (Trabeculectomy group, TG), 20 eyes ...
Efstathios T. Detorakis +3 more
doaj +3 more sources
Clinical Assessment of Automated Non-Contact Tonometer: Interchangeability with Goldmann Applanation Tonometry and Repeatability. [PDF]
Chaglasian M +7 more
europepmc +3 more sources
Comparison between standard Goldmann applanation prism and disposable applanation prism in tonometry [PDF]
Disposable devices are increasingly becoming the preferred choice where possible in contact medical equipment.To evaluate the accuracy of the disposable applanation tonometer head as a potential substitute to the standard Goldmann applanation head.The study was prospective.
Sid Goel +6 more
openalex +3 more sources
Comparison of Intraocular Pressure Measurements with Goldmann Applanation Tonometry, iCare, and Tono-Pen in Young Children with Anterior Segment Abnormalities Under General Anesthesia. [PDF]
Studer MK +4 more
europepmc +3 more sources
The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients. [PDF]
Kyei S +3 more
europepmc +3 more sources
Using Deep Learning to Automate Goldmann Applanation Tonometry Readings. [PDF]
Spaide T +9 more
europepmc +3 more sources