Using Deep Learning to Automate Goldmann Applanation Tonometry Readings. [PDF]
To develop an objective and automated method for measuring intraocular pressure using deep learning and fixed-force Goldmann applanation tonometry (GAT) techniques.Prospective cross-sectional study.Patients from an academic glaucoma practice.Intraocular pressure was estimated by analyzing videos recorded using a standard slit-lamp microscope and fixed ...
Spaide T +9 more
europepmc +6 more sources
Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus [PDF]
Maddalena De Bernardo, Nicola Rosa
doaj +4 more sources
Background. To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) following trabeculectomy. Methods. Thirty eight glaucomatous eyes with a history of trabeculectomy (Trabeculectomy group, TG), 20 eyes ...
Efstathios T. Detorakis +3 more
doaj +3 more sources
Comparison of Rebound and Applanation Tonometry in Eyes With Focal Corneal Edema. [PDF]
ABSTRACT Objective To determine the effect of corneal edema on intraocular pressure (IOP) readings and their accuracy and precision when obtained with handheld rebound and applanation tonometers. Animals and Procedures IOP readings from areas of focal corneal edema were compared to those from clear cornea in 10 eyes of 7 glaucomatous cats in vivo using
Kiland JA +7 more
europepmc +2 more sources
Clinical Assessment of Automated Non-Contact Tonometer: Interchangeability with Goldmann Applanation Tonometry and Repeatability. [PDF]
Chaglasian M +7 more
europepmc +3 more sources
Comparison of Intraocular Pressure Measurements with Goldmann Applanation Tonometry, iCare, and Tono-Pen in Young Children with Anterior Segment Abnormalities Under General Anesthesia. [PDF]
Studer MK +4 more
europepmc +3 more sources
The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients. [PDF]
Kyei S +3 more
europepmc +3 more sources
Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness [PDF]
AIM: To determine the effects of peripheral corneal thickness (PCT) on dynamic contour tonometry(DCT) and Goldmann applanation tonometry (GAT). METHODS: A cross-sectional study.
F. Sáenz-Francés +8 more
openalex +5 more sources
Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature [PDF]
Konstantinos Andreanos, Chryssanthi Koutsandrea, Dimitris Papaconstantinou, Andreas Diagourtas, Andreas Kotoulas, Panagiotis Dimitrakas, Marilita M Moschos First Department of Ophthalmology, University of Athens, “G.
Andreanos K +6 more
doaj +2 more sources
Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice [PDF]
Abstract.Purpose: To compare intraocular pressure (IOP) readings taken using dynamic contour tonometry (DCT) with IOP readings taken with Goldmann applanation tonometry (GAT) in eyes with glaucoma or ocular hypertension.Methods: The present study included 100 eyes in 100 patients with glaucoma or ocular hypertension. After pachymetry DCT and GAT were
Ioannis Halkiadakis +9 more
openalex +4 more sources