Results 61 to 70 of about 83,168 (202)
When the Grid-Following (GFL) and the Grid-Forming (GFM) converters are hybrid-connected to the grid, they are coupled through the grid impedance. During grid faults, the transient characteristics of the two converters become more complex due to this ...
Baoyu Zhai +5 more
doaj +1 more source
Stability Analysis and Enhanced Control of Wind Turbine Generators Based on Hybrid GFL-GFM Control
With the proliferation of wind power generation, the receiving end grids exhibit unprecedented dynamic characteristics, imposing critical stability challenges on grid-connected wind turbine’s converter.
Sijia Huang +4 more
doaj +1 more source
W-band waveguide-packaged InP HEMT reflection grid amplifier [PDF]
This letter presents a 79-GHz broadband reflection-type grid amplifier using spatial power combining to combine the power of 64 unit cells. Each unit cell uses a two-stage cascade configuration with InP HEMTs arranged as a differential pair.
Cheung, Chun-Tung +3 more
core +1 more source
A cooperative control strategy for power quality based on parallel grid-connected converters
Power quality control based on grid-connected converter can effectively utilize the surplus capacity of the converter and improves the benefits. However, existing methods tend to only consider grid-following (GFL) control and fail to fully utilize the ...
LIANG Xiaorui +5 more
doaj +1 more source
Power Quality Improvement Wind Energy System Using Cascaded Multilevel Inverter [PDF]
In this paper, a wind energy conversion system based on a cascaded H-bridge multilevel inverter (CHBMLI) topology has been proposed to be used for the grid interface of large split winding alternators (SWAs).
A. S., Kumar, J.S., Sathiyanarayanan
core +2 more sources
Power balancing and dc fault ride through in DC grids with dc hubs and wind farms [PDF]
Acknowledgment This project was funded by European Research Council under the Ideas program in FP7; grant no 259328, 2010.Peer ...
Jovcic, Dragan, Lin, Weixing
core +1 more source
The high penetration of renewable energy sources (RESs) and power electronics devices has led to a continuous decline in power system stability. Due to the instability of grid-following converters (GFLCs) in weak grids, the grid-forming converters (GFMCs) have gained widespread attention featuring their flexible frequency and voltage regulation ...
Lifeng Qiu +7 more
openaire +2 more sources
This paper offers a systematic approach to understanding the performance of the grid-forming inverter in both isolated and hybrid configuration with a grid-following inverter in low-voltage distribution network. While most existing studies concentrate on
Qusay Salem +4 more
doaj +1 more source
Modern power grids are increasingly challenged by the lack of inertia caused by the high penetration of renewable energy sources (RES). This low inertia leads to reduced frequency stability and greater vulnerability to disturbances. To address this issue,
Mina Valikhany +3 more
doaj +1 more source
The Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability
This paper explains the working principles, supported by simulation results, of a new converter topology intended for HVDC applications, called the alternate arm converter (AAC).
Critchley, R +6 more
core +1 more source

