Results 41 to 50 of about 20,876 (237)
Influence of Load Dynamics on Converter-Dominated Isolated Power Systems
The operation of isolated power systems with 100% converter-based generation requires the integration of battery energy storage systems (BESS) using grid-forming-type power converters.
José Gouveia +2 more
doaj +1 more source
On the robustness of ultra-high voltage 4H-SiC IGBTs with an optimized retrograde p-well [PDF]
The robustness of ultra-high voltage (>10kV) SiC IGBTs comprising of an optimized retrograde p-well is investigated. Under extensive TCAD simulations, we show that in addition to offering a robust control on threshold voltage and eliminating punch ...
Antoniou, M. +5 more
core +1 more source
This review provides an overview of bio‐based polymer sources, their unique functional properties and their environmental impact, and addresses their role as sustainable alternatives. It discusses end‐of‐life options, including composting and anaerobic digestion for renewable energy.
Sabina Kolbl Repinc +8 more
wiley +1 more source
The grid-forming converter has voltage source characteristics,providing damping and frequency support to high-impedance weak grids,and demonstrates good stability. However,instability may occur under low impedance grids.
Yongkang CHEN +5 more
doaj +1 more source
ABSTRACT Objective Accurate localization of epileptogenic tubers (ETs) in patients with tuberous sclerosis complex (TSC) is essential but challenging, as these tubers lack distinct pathological or genetic markers to differentiate them from other cortical tubers.
Tinghong Liu +11 more
wiley +1 more source
Laser surface texturing significantly improves the corrosion resistance and mechanical strength of 3D‐printed iron polylactic acid (Ir‐PLA) for marine applications. Optimal laser parameters reduce corrosion by 80% and enhance tensile strength by 25% and ductility by 15%.
Mohammad Rezayat +6 more
wiley +1 more source
This paper analyzes the fault equivalent models of grid-following and grid-forming converters under various fault conditions. A novel fault calculation method for MMC-HVDC grid-forming systems integrated with 100% renewable energy generation is proposed.
Bohao Zhou +5 more
doaj +1 more source
Stability Analysis of Converter Control Modes in Low-Inertia Power Systems [PDF]
This paper deals with the small-signal stability analysis of converter control modes in low-inertia power systems. For this purpose, a detailed differential-algebraic equation model of the voltage source converter and its control scheme is developed ...
Aristidou, P +3 more
core +1 more source
Herein, environmental scanning electron microscopy (ESEM) is discussed as a powerful extension of conventional SEM for life sciences. By combining high‐resolution imaging with variable pressure and humidity, ESEM allows the analysis of untreated biological materials, supports in situ monitoring of hydration‐driven changes, and advances the functional ...
Jendrian Riedel +6 more
wiley +1 more source
Power grid pattern is expected to evolve from generator-based power systems towards converter-based systems in the forthcoming decades. Therefore, grid-forming converters will be pertinent to interconnected power grids in pursuance of enhancement their ...
Mohamed Ahmed +4 more
doaj +1 more source

