Results 31 to 40 of about 2,892,347 (284)
The analysis of long-term borehole heat exchanger system exploitation
The key issue in designing borehole heat exchangers (BHE) is the long-term performance of the ground source heat pump (GSHP) systems. The performance directly reflects economic profitability and depends on a large number of parameters including rock ...
Marek Jaszczur, Tomasz Śliwa
doaj +1 more source
Heat Transfer Modeling of the Ground Heat Exchangers for the Ground-Coupled Heat Pump Systems [PDF]
Ground-coupled heat pump (GCHP) systems have been gaining increasing popularity for space air conditioning in buildings due to their reduced energy and maintenance costs. The efficiency of GCHP systems is inherently higher than that of the traditional options because it utilizes the ground which maintains a relatively stable temperature all the year ...
Yi Man, Ping Cui, Zhaohong Fang
openaire +1 more source
Fouling Detection in Heat Exchangers [PDF]
This paper deals with the design of a nonlinear observer for the purpose of detecting the fouling phenomenon that commonly occurs in heat exchangers. First, the general model of the heat exchanger is presented in terms of partial differential equations ...
K. Busawon +9 more
core +1 more source
The energy source for heat pumps with vertical heat exchangers
The paper presents the ground temperature analysis, heat flows and energy transferred from the soil massif by the vertical ground heat exchangers (VGHE). Three cases – with one, two and three vertical heat exchangers were compared.
Rynkowski Piotr
doaj +1 more source
A Model of a Diaphragm Wall Ground Heat Exchanger
Ground thermal energy is a sustainable source that can substantially reduce our dependency on conventional fuels for heating and cooling of buildings.
Ida Shafagh +4 more
doaj +1 more source
Methodology for estimating the ground heat absorption rate of Ground Heat Exchangers
Abstract In Ground Source Heat Pump systems, the heat exchange rate is an important factor with regard to the initial cost of the system. When the Ground Heat Exchanger (GHE) is installed in a lithology with high thermal properties in the presence of groundwater, the heat exchange rates are larger than in the cases with poor thermal response of the ...
Stylianou, II +4 more
openaire +3 more sources
We present robust protocols for the preparation of supported lipid bilayers (SLBs) incorporating either Salmonella smooth LPS or outer membrane vesicles (OMVs). We use a combination of quartz crystal microbalance with dissipation (QCM‐D) and fluorescence microscopy to both characterize the SLBs of various compositions and to probe their interactions ...
Hudson P. Pace +6 more
wiley +1 more source
Lessons Learned from Labyrinth Type of Air Preconditioning in Exergy-Aware Solar Greenhouses
An exergy-based model hypothesizes that labyrinth-type ground-to-air heat exchangers are responsible for carbon dioxide emissions if the exergy of power demand concerning ancillaries like fans and pumps exceeds the thermal exergy gain.
Birol Kilkis
doaj +1 more source
Research on ground-coupled heat exchangers [PDF]
Ground source heat pump (GSHP) has been considered as one of the most promising low-carbon technologies for building heating, ventilation and air conditioning (HVAC) applications at present. Since a GSHP relies heavily on the performance of ground-coupled heat exchangers (GCHEs), this paper was focused on GCHEs key technical issues and presented ...
Jiufa Chen +4 more
openaire +2 more sources
The process of internalization of the Shiga toxin A subunit via formation of a complex with the Shiga toxin B subunit, which specifically binds to the Gb3 receptor. The peptide is designed to act as a carrier of drugs into cancer cells. Here, we explored the potential of peptides derived from the catalytic A subunit of Shiga toxin (STxA) to be drug ...
Giulia Opassi +6 more
wiley +1 more source

