Results 41 to 50 of about 2,892,347 (284)
Ground temperature at shallow depth (< 50 m) is not stable, nor in space, neither in time, and its behaviour is the result of superimposition of effects of heat pulses of different origin: solar, geothermal and anthropic. The correct assessment of ground
Francesco Tinti +6 more
doaj +1 more source
Application and Design Aspects of Ground Heat Exchangers
With the constant increase in energy demand, using renewable energy has become a priority. Geothermal energy is a widely available, constant source of renewable energy that has shown great potential as an alternative source of energy in achieving global ...
Luka Boban +3 more
doaj +1 more source
Emerging experimental and computational methods for studying redox‐regulated structural transitions
Redox reactions can reshape proteins and alter how they behave in cells, with important consequences for health and disease. This review explores emerging experimental and computational approaches for discovering these redox‐sensitive protein switches, revealing their structural effects, and predicting their behavior, opening new opportunities to ...
Tasneem Rass +2 more
wiley +1 more source
Development and application of test cases for comparing vertical ground heat exchanger models [PDF]
The main objective of this paper is to establish a set of test cases for analytical verifications and intermodel comparisons of ground heat exchanger (GHX) models used in building simulation programs. Several test cases are suggested.
Bernier, M. +2 more
core +5 more sources
Ground source heat pump systems are one of the renewable energy heat utilization technologies that can reduce the energy for HVAC and hot water supplies and consequently mitigate the progression of global warming.
Takao Katsura +3 more
doaj +1 more source
Laboratory thermal conductivity measurements on gravel sample
Modern Ground Source Heat Pumps (GSHPs) systems must be designed by taking into account the ground thermal properties, in order to properly plan the capability of the heat pumps to transfer calories through the Ground Source Heat Exchangers (GSHE) to the
Antonio Galgaro +3 more
doaj +1 more source
A horizontal ground heat exchanger installation is less expensive than a vertical ground heat exchanger, but more land is required. The system’s required pipe length and land area can be decreased by improving the system.
Reza Saeidi +3 more
doaj +1 more source
Importin 7 mediates the nuclear import of HIV‐1 integrase via a specific interacting interface
HIV‐1 integrase enables viral DNA integration into the host genome. By binding to the core domain of the host protein Importin 7 via its C‐terminal domain, the integrase is transported across the nuclear membrane into the nucleus, where integration of the viral genome into host DNA takes place. This translocation is a critical step for subsequent viral
Juana Bana +5 more
wiley +1 more source
We report the first β‐glucosidase with demonstrated hydrolytic activity on an N‐linked glycopyranoside. The enzyme, native to maize, was biochemically characterised for this novel reaction, and structural modelling of the enzyme–substrate complex revealed several clues to the underlying reduced catalytic rate relative to its native O‐glycopyranoside ...
Hani Gharabli +3 more
wiley +1 more source
The thermal performance of foundation piles used as heat exchangers in ground energy systems
Pile heat exchangers are expected to make a significant contribution to meeting UK and EU renewable energy and carbon dioxide reduction targets. However, design for the thermal capacity of pile heat exchangers has to date been largely based on methods ...
Loveridge, F.
core +1 more source