The ideal grounding resistance to avoid from lightning strikes is R < 1 Ω . This study aims to measure grounding resistance and analyze the resistance grounding at different depths.
Hambali Hambali, Yeza Permata Sari
doaj +1 more source
Environmental effects on the performance of electrical grounding systems [PDF]
Effects of surrounding environment of grounding electrode locations on the performance of overall grounding system has been studied. Copper rods were buried at 25 different locations with various environmental settings and their respective variations in ...
Ab Kadir, Mohd Zainal Abidin +3 more
core +1 more source
Analysis of the effect of explosion grounding electrode on grounding resistance reduction
Developing cracks in the soil by means of explosions in the holes, as is called the explosion grounding electrode in this study, is a very effective way to reduce the grounding resistance in the area with high resistivity soil.
Yongli Wang +4 more
doaj +1 more source
In view of problems of limited terrain, short effective dispersion length, and low resistance reduction efficiency in the extensional resistance reduction of the grounding grid of incoming line section of mine substation, a resistance reduction method ...
XIE Hongping +5 more
doaj +1 more source
Monte Carlo evaluation of the impact of subsequent strokes on backflashover rate [PDF]
The paper deals with the impact of subsequent strokes on the backflashover rate (BFR) of HV overhead transmission lines (OHLs), assessed by means of an ATP-EMTP Monte Carlo procedure.
Gatta, Fabio Massimo +3 more
core +1 more source
Tower impulse grounding resistance measurement based on multiple frequency impedance
Tower impulse grounding resistance is important for judging the lightning protection performance of transmission lines. Therefore, it is significant to accurately measure the tower impulse grounding resistance. Existing measurement methods mainly contain
Yihua Dan +5 more
doaj +1 more source
Tower grounding improvement versus line surge arresters: comparison of remedial measures for high-BFOR subtransmission lines [PDF]
This paper presents a technical/economic comparison between remedial measures aimed at improving the lightning performance of an existing Italian three-phase 150-kV overhead line.
GATTA, Fabio Massimo +4 more
core +1 more source
Simplified conservative testing method of touch and step voltages by multiple auxiliary electrodes at reduced distance [PDF]
Grounding systems (GSs) must be tested periodically in order to maintain the touch voltage (TV) and step voltage (SV) below a safe value in all of the zones of the installation.
Araneo, Rodolfo +4 more
core +1 more source
Analysis on frequency and impulse characteristics of grounding grid
Studying the frequency and impulse characteristics of grounding grids is of great reference value for the optimal design of the substation. As the frequency increasing, the variation trend of the grounding resistance under different conditions is not ...
Mengmeng Su +3 more
doaj +1 more source
A novel fault location method for a cross-bonded hv cable system based on sheath current monitoring [PDF]
In order to improve the practice in the operation and maintenance of high voltage (HV) cables, this paper proposes a fault location method based on the monitoring of cable sheath currents for use in cross-bonded HV cable systems.
Huang, Xiaojun +6 more
core +1 more source