Results 11 to 20 of about 329,894 (240)

Stamina of a non-gasketed flange joint under combined internal pressure and axial loading [PDF]

open access: yes, 2008
The performance of a bolted flange joint is characterized mainly by its 'strength' and 'sealing capability'. A number of numerical and experimental studies have been conducted to study these characteristics under internal pressure loading conditions ...
Abid, M.   +5 more
core   +4 more sources

Cold-formed steel sections with web openings subjected to web crippling under two-flange loading conditions — Part II : Parametric study and proposed design equations [PDF]

open access: yes, 2012
A parametric study of cold-formed steel sections with web openings subjected to web crippling was undertaken using finite element analysis, to investigate the effects of web holes and cross-section sizes on the web crippling strengths of channel sections
Uzzaman, Asraf   +11 more
core   +4 more sources

Leakage analysis of gasketed flange joints under combined internap pressure and thermal loading [PDF]

open access: yes, 2011
Leakage in Gasketed Flanged Joints (GFJs) have always been a great problem for the process industry. The sealing performance of a GFJ depends on its installation and applied loading conditions.
Khan, Kamran Ahmed   +3 more
core   +3 more sources

Non Surgical Correction of Mandibular Deviation and Neuromuscular Coordination after Two years of Mandibular Guidance Therapy: A Case Report [PDF]

open access: yesJournal of Clinical and Diagnostic Research, 2015
Carcinomas of the mandible may require resection of a segment of bone (continuity defect), partial removal of bone (discontinuity defect), tongue, and floor of the mouth and muscle attachments.
Bijay Singh   +3 more
doaj   +1 more source

A parametric study of metal-to-metal contact flanges with optimised geometry for safe stress and no-leak conditions [PDF]

open access: yes, 2004
This paper presents the results of a parametric study of the behaviour of metal-to-metal contact flanges that have different surface profiles. Using a finite element analysis approach, the important stress values in the flange and bolts and flange ...
Abid, M., Nash, D.H.
core   +4 more sources

Mechanical Analysis of Deformation Law in the Flange Area of Box-Shaped Parts during Deep Drawing

open access: yesMachines, 2022
The investigation of deformation law is the theoretical basis for analyzing instability wrinkling and forming performance during the sheet-metal-forming process.
Duan Chen   +3 more
doaj   +1 more source

Rehabilitation of a Hemimandibulectomy Patient with an Overlay Denture: A Case Report [PDF]

open access: yesJournal of Clinical and Diagnostic Research, 2018
Prosthetic rehabilitation of hemimandibulectomy patient, with an overlay denture, restores missing skeletal, dental structures, muscle imbalance, maxillomandibular relationship and occlusion.
Siva Prakash Dhanaraj, H Annapoorni
doaj   +1 more source

A novel speech prosthesis for mandibular guidance therapy in hemimandibulectomy patient: A clinical report

open access: yesContemporary Clinical Dentistry, 2016
Treating diverse maxillofacial patients poses a challenge to the maxillofacial prosthodontist. Rehabilitation of hemimandibulectomy patients must aim at restoring mastication and other functions such as intelligible speech, swallowing, and esthetics ...
Raghavendra Adaki   +3 more
doaj   +1 more source

Prosthetic management of a hemi-Mandibulectomy patient

open access: yesIndian Journal of Dental Sciences, 2018
This case report describes the prosthodontic management of a patient that has undergone hemimandibulectomy with a provisional training appliance followed by definitive flange prosthesis.
Shweta Choudhary   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy