Results 21 to 30 of about 1,506,118 (205)
Entanglement Spectrum and Entanglement Thermodynamics of Quantum Hall Bilayers at nu=1 [PDF]
We study the entanglement spectra of bilayer quantum Hall systems at total filling factor nu=1. In the interlayer-coherent phase at layer separations smaller than a critical value, the entanglement spectra show a striking similarity to the energy spectra
B. I. Halperin +2 more
core +2 more sources
The Precision of Half-value Layer Measurement on Mammography
The half-value layer (HVL) is an important index of the image quality or radiation risk in mammography. Radiation risk of the breast tissue is evaluated with the average glandular dose. The HVL index is indispensable for the average glandular dose computations.
Rie, Ishii +4 more
openaire +3 more sources
Determining X-Ray Effective Energy in Linear Accelerator (LINAC) Radiotherapy Instrument
This research in determining x-ray effective energy in linear accelerator (Linac) radiotherapy device was done using copper plates at different thicknesses by determining the Half Value Layer (HVL) for each energy. The purpose of this research is to know
Fauziah Fauziah, Bualkar Abdullah
doaj +1 more source
This study aimed to determine the contribution of B2O3/CdO substitution on gamma-ray attenuation behaviors of 46V2O5–46P2O5–(8−x)B2O3–xCdO (x = 0–8 mol%) glass system.
H.O. Tekin +8 more
doaj +1 more source
This study examines the physical, mechanical, microstructural, and attenuation properties of high-density concrete exposed to temperatures ranging from 200°C to 1200°C.
Muhammad Nasir Ayaz Khan +8 more
doaj +1 more source
The key role of smooth impurity potential in formation of hole spectrum for p-Ge/Ge_{1-x}Si_x heterostructures in the quantum Hall regime [PDF]
We have measured the temperature (0.1
Arapov Yu G +24 more
core +1 more source
Reduction of the systematic error when determining the characteristics of the reference X-ray radiation fields is an essential task according to the ISO 4037-1:2019 standard.
A. A. Zaharadniuk +2 more
doaj +1 more source
Methodology study for determining the half-value layer using the Monte Carlo code PHITS
For most purposes, the quality of a beam can be specified in terms of the half-value layer (HVL), which is the thickness of material required to reduce the air kerma to half, at one meter from the source, from a unidirectional beam of infinitesimal ...
Ronald Soares, Marco Aurélio Lacerda
doaj +1 more source
Comparison of X-Ray Attenuation Performance, Antimicrobial Properties, and Cytotoxicity of Silicone-Based Matrices Containing Bi2O3, PbO, or Bi2O3/PbO Nanoparticles [PDF]
Background: Application of the nanomaterials to preparing X-ray shields and successfully treating multiresistant microorganisms has attracted great attention in modern life.Objective: This study aimed to prepare flexible silicone-based matrices ...
Baharak Divband +4 more
doaj +1 more source
Effects of charging and electric field on the properties of silicene and germanene [PDF]
Using first-principles Density Functional Theory calculations, we showed that electronic and magnetic properties of bare and Ti adatom adsorbed single-layer silicene and germanene, which are charged or exerted by a perpendicular electric field are ...
Ciraci, S. +2 more
core +2 more sources