Results 81 to 90 of about 10,851 (310)
Weaving Intelligence: Thermally Drawn Multimaterial Fibers Toward AI‐Enabled Smart Textiles
Thermally drawn multimaterial fibers are rapidly advancing as intelligent structural units for next‐generation smart textiles. Integrating multimaterial architectures with neuromorphic and spiking‐neural‐network principles enables fabrics that can sense, compute, and adapt autonomously.
Vuong Dinh Trung +9 more
wiley +1 more source
Intrascleral haptic fixation of intraocular lens (IOL) is an extremely useful technique to provide visual rehabilitation in eyes with inadequate capsular support.
Rajesh Sinha +2 more
doaj +1 more source
Autologous blood-assisted scleral fixation of intraocular lens
In this technique, the lamellar scleral tunnel is fashioned to cover IOL haptics and autologous blood is used to close the conjunctiva, which alleviates the need for fibrin glue.
Avadhesh Oli, Divya Balakrishnan
doaj +1 more source
Physically co-located haptic interaction with 3D displays
Studies indicate that haptic interaction with a computer generated virtual scene may become more intuitive by aligning (co-locating) the visual and haptic workspaces so that the visual and haptic feedback coincide as they do in the real world. Co-located
Stefan Seipel +7 more
core +1 more source
Layer orientation dictates charge transport in 2D conjugated metal–organic frameworks, yet controllable methods remain scarce. We report surfactant monolayer‐assisted on‐water synthesis of cm2‐scale Ni‐HHTP films with programmable face‐on and edge‐on orientations.
Jianjun Zhang +22 more
wiley +1 more source
This review explores advances in wearable and lab‐on‐chip technologies for breast cancer detection. Covering tactile, thermal, ultrasound, microwave, electrical impedance tomography, electrochemical, microelectromechanical, and optical systems, it highlights innovations in flexible electronics, nanomaterials, and machine learning.
Neshika Wijewardhane +4 more
wiley +1 more source
Intraoperative aberrometry-assisted refractive optimization of SFIOL
Scleral-fixated intraocular lens (SFIOL) is a widely used technique for IOL implantation in patients where capsular support is insufficient. Most surgeons have shifted away from sutured to sutureless SFIOL techniques where haptics of a multifocal IOL are
Saurabh Verma +4 more
doaj +1 more source
Pervasive haptics: science, design, and application
This book examines the state of the art in diverse areas of haptics (touch)-related research, including the psychophysics and neurophysiology of haptics, development of haptics displays and sensors, and applications to a wide variety of fields such as ...
Saga, Satoshi +2 more
core +1 more source
Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu +8 more
wiley +1 more source
TacBalloon: Soft Balloon Catheter Tactile Sensor With Simulation-Driven Learning
Minimally invasive surgery has seen rapid advancements in recent years, with various medical instruments such as catheters and endoscopes developed to reduce patient trauma.
Satoshi Nagasawa +3 more
doaj +1 more source

